Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: STORAGE BATTERY SYSTEMS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of STORAGE BATTERY SYSTEMS, INC. in N56 W16665 RIDGEWOOD DRIVE, MENOMONEE FALLS, WI 53051 (NAICS 335911). OSHA activity number 331110502.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Storage Battery Systems, INC. for free Get an email when a new federal OSHA severe-injury report for Storage Battery Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N56 W16665 RIDGEWOOD DRIVE
City
MENOMONEE FALLS
State
WI
ZIP
53051
Mailing
N56 W16665 RIDGEWOOD DRIVE, MENOMONEE FALLS, WI 53051
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335911
Employees
32
Ownership type
Private (A)

3 citations on file for this inspection.

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 4, 2012
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a)  The compressed air nozzle being used for cleaning off debris from battery systems in the work cell next to the washing booth area was not equipped with relief when dead ended measured at 40 p.s.i.g..
Recent events (2)
  • · I (S) $1470
  • · Z (S) $2100

1910.22 D01

Other-than-serious 2 instances 6 exposed
Issued
Apr 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):     On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    a)  Load rating signs were not posted for the storage area located above the parts room.    b)  Load rating signs were not posted for the storage area located above the shipping office.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 4 exposed
Issued
Apr 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    a)  The electrical switch box for the compressor unit was missing six knockout plugs that would allow access to the live electrical wiring contained inside.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Storage Battery Systems, INC.'s full OSHA safety record →