OSHA Inspection: STERLING AUTO BODY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STERLING AUTO BODY in 6870 SOUTH JORDAN ROAD, CENTENNIAL, CO 80112 (NAICS 811121). OSHA activity number 331110650.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Auto Body for free Get an email when a new federal OSHA severe-injury report for Sterling Auto Body is published. One employer, no account, unsubscribe in one click.
Establishment
STERLING AUTO BODY
Site address
6870 SOUTH JORDAN ROAD
City
CENTENNIAL
State
CO
ZIP
80112
Mailing
6870 SOUTH GORDON ROAD, CENTENNIAL, CO 80112
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.36 G02

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
May 9, 2012
Abate by
May 31, 2012
Penalty
Initial $3,400 · Current $0 Reduced
29 CFR 1910.36(g)(2):  Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:    a)  On or about January 6, 2012, and at times prior, employees were exposed to restricted egress hazards from having an exit access walkway less than 28 inches in width in the refinishing area of the shop.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3400

1910.303 G01 I A

Other-than-serious 1 instance 15 exposed
Issued
May 9, 2012
Abate by
May 31, 2012
Penalty
Initial $0 · Current $1,275
29 CFR 1910.303(g)(1)(i)(A):  For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    a)  On or about January 6, 2012, and at times prior, the employer did not allow for adequate clearance for electrical panel MDP - 19,21,23. Panel was found in direct proximity of a walkway and was less than 30 inches from a spray booth enclosure.
Recent events (2)
  • · I (O) $1275
  • · Z (S) $0

1910.134 G01 I A

Other-than-serious 1 instance 3 exposed
Issued
May 9, 2012
Abate by
May 16, 2012
Penalty
Initial $850 · Current $850
29 CFR 1910.134(g)(1)(i)(A):  Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    a)  On or about January 6, 2012, and at times prior, employees were exposed to respiratory hazards during spray painting and sanding operations from wearing a half face filtering facepiece respirator with facial hair that interfered with the seal on the facepiece.
Recent events (2)
  • · I (O) $850
  • · Z (O) $850

View Sterling Auto Body's full OSHA safety record →