GLENCOE, IL ·
OSHA Inspection: GRAVITY STUCCO, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GRAVITY STUCCO, INC. in 130 WHITEBRIDGE HILL DRIVE, GLENCOE, IL 60022 (NAICS 238310). OSHA activity number 331110791.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GRAVITY STUCCO, INC.
- Site address
- 130 WHITEBRIDGE HILL DRIVE
- City
- GLENCOE
- State
- IL
- ZIP
- 60022
- Mailing
- 305 EAST STREAMWOOD BLVD., STREAMWOOD, IL 60107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Jan 25, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $4,200 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Employees were exposed to the hazard of falling approximately 20 feet while working from scaffolding that was not fully planked. b) Employees were exposed to the hazard of falling approximately 14 feet while working from scaffolding that was not fully planked. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1800
- · Z (S) $4200
1926.451 F03
- Issued
- Jan 25, 2012
- Abate by
- Mar 15, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) The employer did not have a competent person inspect scaffolding and scaffolding components before the work shift. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $3000
1926.451 G01
- Issued
- Jan 25, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $4,200 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) Employees were exposed to the hazard of falling approximately 20 feet while working from scaffolding without fall protection. b) Employees were exposed to the hazard of falling approximately 14 feet while working from scaffolding without fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2000
- · Z (S) $4200
1926.501 B13
- Issued
- Jan 25, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $4,200 · Current $1,900 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Employees were exposed to the hazard of falling approximately 22 feet while working from a roof deck without the use of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.