PEWAUKEE, WI —
OSHA Inspection: SANCHEZ ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SANCHEZ ROOFING, INC. in N38 W22747 WYNDEMERE DR., PEWAUKEE, WI 53072 (NAICS 238160). OSHA activity number 331111245.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SANCHEZ ROOFING, INC.
- Site address
- N38 W22747 WYNDEMERE DR.
- City
- PEWAUKEE
- State
- WI
- ZIP
- 53072
- Mailing
- 324 BONUS AVE., BELVIDERE, IL 61008
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Feb 24, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $1,980 · Current $0 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from fallingor flying objects, or from electrical shock and burns, shall be protected by protective helmets. (a) At the site address employees were not using head protection when working under material and equipment.
Recent events (2)
- — I (O) $0
- — Z (S) $1980
1926.1053 B01
- Issued
- Feb 24, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $2,640 · Current $1,320 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. (a) At the site address employees were using an extension ladder that did not extend at least 3' above the landing surface. Employees were using the extension ladder to access the roof in order to conduct roofing work.
Recent events (2)
- — I (S) $1320
- — Z (S) $2640
1926.501 B13
- Issued
- Feb 24, 2012
- Abate by
- Feb 27, 2012
- Penalty
- Initial $7,920 · Current $3,960 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provisionin paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it isinfeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets therequirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fallprotection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complieswith 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. (a) At the site address the employees were not using fall protection when conducting roofing work on a residential building. Sanchez Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 314034240, citation number 01, item number 001 and was affirmed as a final order on May 8, 2010, with respect to a workplace location at 2225 W. Main St., St. Charles, IL 60174.
Recent events (2)
- — I (R) $3960
- — Z (R) $7920
More inspections at Sanchez Roofing, INC.