Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VIBRO DYNAMICS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VIBRO DYNAMICS CORPORATION in 2443 BRAGA DRIVE, BROADVIEW, IL 60153 (NAICS 423830). OSHA activity number 331111385.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vibro Dynamics Corporation for free Get an email when a new federal OSHA severe-injury report for Vibro Dynamics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2443 BRAGA DRIVE
City
BROADVIEW
State
IL
ZIP
60153
Mailing
2443 BRAGA DRIVE, BROADVIEW, IL 60153
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
18
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 exposed
Issued
Mar 22, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) employees from hazard(s) created by rotating parts.    a. Facility - On or about January 5, 2012, employees were required to operate the Jet lathe with an unguarded chuck. The employees were thereby exposed to the hazard of rotating/moving parts.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.213 B03

Serious Gravity 5 1 exposed
Issued
Mar 22, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.213(b)(3): On applications where injury to the operator might result if motors were to restart after power failures, provision shall be made to prevent machines from automatically restarting upon restoration of power.    a. Facility - On or about January 5, 2010, employees were required to use a Craftsman radial arm saw.  The radial arm saw did not have a magnetic motor starter.  Employees were thereby exposed to hazards associated with drive motor engagement after power failures.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.147 C06 II

Other-than-serious 2 exposed
Issued
Mar 22, 2012
Abate by
May 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed.  The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.    a.  Entire facility - On or about January 5, 2011, the employer had not adequately certified periodic inspections of the established energy control procedures in place for employees who perform servicing and maintenance of equipment.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331111385.