NILES, OH —
OSHA Inspection: TRUMBULL METAL SPECIALTIES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TRUMBULL METAL SPECIALTIES in 643 HENRY ST., NILES, OH 44446 (NAICS 331513). OSHA activity number 331111674.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRUMBULL METAL SPECIALTIES
- Site address
- 643 HENRY ST.
- City
- NILES
- State
- OH
- ZIP
- 44446
- Mailing
- 643 HENRY ST., NILES, OH 44446
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 50
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.37 B02
- Issued
- Mar 8, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": On 1/12/2012, the northeast side of the building had a doorway that was not marked as an exit discharge.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.37 B05
- Issued
- Mar 8, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): On 1/12/2012, the door to the compressor room on the westside of the building had no markings indicating that it was not an exit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Mar 8, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On 1/12/2012, the forklift used to load and unload the Tinker Omega mixer had a personnel carrier with damaged and seperated fall protection.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.157 C04
- Issued
- Mar 8, 2012
- Penalty
- Initial $1,785 · Current $1,070 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: On 1/12/2012, the portable fire extinguisher by the Pangborn shot blaster was not charged and operable.
Recent events (2)
- — I (S) $1070
- — Z (S) $1785
1910.212 A01
- Issued
- Mar 8, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On 1/12/2012, the Rockewell drill press in the maintenance room did not have rotating chuck and tool guarding.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.212 B
- Issued
- Mar 8, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On 1/12/2012, the Rockwell drill press in the maintenance shop was not anchored to the work floor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A05
- Issued
- Mar 8, 2012
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: On 1/12/2012, the personnel fan used at the induction furnace area had inadequate guarding with 2 inch openings.
Recent events (2)
- — I (S) $0
- — Z (S) $1785
1910.305 B02 I
- Issued
- Mar 8, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On 1/12/2012, there was a dual electrical toggle switch and a duplex receptacle in the new production office that did not have a cover plates.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.305 B01 II
- Issued
- Mar 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On 1/12/2012, the electrical disconnect switch near the Pangborn shot blaster had two unused openings and was damaged.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Trumbull Metal Specialties
View Trumbull Metal Specialties's full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331111674.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.