Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: XENIA FOUNDRY & MACHINE COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of XENIA FOUNDRY & MACHINE COMPANY, INC. in 252 N WEST ST, XENIA, OH 45385 (NAICS 332111). OSHA activity number 331111815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Xenia Foundry & Machine Company, INC. — free Get an email when a new federal OSHA severe-injury report for Xenia Foundry & Machine Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
252 N WEST ST
City
XENIA
State
OH
ZIP
45385
Mailing
252 N WEST ST, XENIA, OH 45385
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332111
Employees
22
Ownership type
A

3 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2012
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.212(a)(5):     Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above thefloor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch.    a) Blower fan cover for the transformer in the electrical room had an opening which allowed employees' fingers to enter, exposing them to rotating blades.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.219 C02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Feb 9, 2012
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.219(c)(2)(i):     All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform,excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by atrough enclosing sides and top or sides and bottom of shafting as location requires.    a) Vibrator shaft for the Sieve machine was not guarded to prevent employees exposure to rotating parts.  b) Shaft for the air exchanger main motor drive was not guarded exposing employees to rotating parts.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 9, 2012
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings shall be effectively closed.      a) The knockout on the electrical disconnect box in the main power room was not closed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1785

View Xenia Foundry & Machine Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331111815.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.