EAU CLAIRE, WI ·
OSHA Inspection: LITHO SPECIALISTS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LITHO SPECIALISTS, INC in 2726 MONDOVI ROAD, EAU CLAIRE, WI 54701 (NAICS 323110). OSHA activity number 331112086.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LITHO SPECIALISTS, INC
- Site address
- 2726 MONDOVI ROAD
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54701
- Mailing
- 2726 MONDOVI ROAD, EAU CLAIRE, WI 54701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 14
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.147 C01
- Issued
- Jun 6, 2012
- Abate by
- Jul 19, 2012
- Penalty
- Initial $1,800 · Current $990 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Production area; The employer did not develop, implement, or maintain an energy control (lockout/tagout) program.
Recent events (2)
- · I (S) $990
- · Z (S) $1800
1910.212 A01
- Issued
- Jun 6, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $1,800 · Current $990 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Production area; Rotating parts on the Chief 15 printing press were not guarded. A side panel on the side of the printing press was removed.
Recent events (2)
- · I (S) $990
- · Z (S) $1800
1910.219 D01
- Issued
- Jun 6, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Production area; A power transmission pulley on an Original Heidelberg windmill printing press was not guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Jun 6, 2012
- Abate by
- Jun 13, 2012
- Penalty
- Initial $2,400 · Current $1,320 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: (a) Production area, O&M folding machine; A relocatable power tap was used in place of permanently installed wiring.
Recent events (2)
- · I (S) $1320
- · Z (S) $2400
1910.305 G02 II
- Issued
- Jun 6, 2012
- Abate by
- Jun 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: (a) Production area, O&M folding machine; A light duty (18/3, type SJ) flexible cord was repaired with electrical tape.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G02 III
- Issued
- Jun 6, 2012
- Abate by
- Jun 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) Production area, O&M folder; A flexible cord connected to the O&M folder did not have strain relief.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 E01
- Issued
- Jun 6, 2012
- Abate by
- Jul 19, 2012
- Penalty
- Initial $1,800 · Current $990 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Throughout the facility; The employer did not develop or maintain a written hazard communication program.
Recent events (2)
- · I (S) $990
- · Z (S) $1800
1910.1200 F05 I
- Issued
- Jun 6, 2012
- Abate by
- Jun 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a) Throughout the production area; Secondary chemical conatainers of Petrogum and 205 Deglazer were not labeled.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Jun 6, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets (a) Throughout the facility; Employee chemical training and information was not provided.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.110 F02 II
- Issued
- Jun 6, 2012
- Abate by
- Jun 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(f)(2)(ii): Liquefied petroleum gas container(s) stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people: (a) Production area; One compressed gas cylinder of liquefied petroleum gas was stored directly next to an exit.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 323110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331112086.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.