LITTLETON, CO —
OSHA Inspection: SOUTHERN VENTURES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SOUTHERN VENTURES, INC. in 9843 TITAN COURT, A, LITTLETON, CO 80125 (NAICS 811121). OSHA activity number 331112094.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHERN VENTURES, INC.
- Site address
- 9843 TITAN COURT, A
- City
- LITTLETON
- State
- CO
- ZIP
- 80125
- Mailing
- 9843 TITAN COURT, A, LITTLETON, CO 80125
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Apr 12, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about February 7, 2012, and at times prior, the employees used respirators for spray painting activities without the employer providing a respiratory protection program.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.134 K06
- Issued
- Apr 12, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) On or about February 7, 2012, and at times prior, employees voluntarily wore respirators for sanding tasks and the employer had not given them required information about voluntary respirator use.
Recent events (1)
- — Z (S) $0
1910.244 A02 III
- Issued
- Apr 12, 2012
- Abate by
- Apr 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(2)(iii): Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack: (a) On or about January 10, 2012, and at times prior, an employee was exposed to crushing hazards while used a hydraulic jack to lift a vehicle and did not secure the vehicle in the lifted position.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 12, 2012
- Abate by
- Apr 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about January 10, 2012, and at times prior, employees were exposed to shock and burn hazards from an extension cord in use with a welder where the insulation was pulled back from the plug.
Recent events (1)
- — Z (S) $0
1910.333 B02 III A
- Issued
- Apr 12, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed: (a) On or about February 7, 2012, and at times prior an employee did not apply a positive means of locking out a light circuit before replacing light ballasts throughout the garage.
Recent events (1)
- — Z (S) $0
1910.303 G01
- Issued
- Apr 12, 2012
- Abate by
- Apr 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about January 10, 2012 and at times prior, electrical boxes on the north wall of the garage were blocked.
Recent events (1)
- — Z (O) $0
More inspections at Southern Ventures, INC.
View Southern Ventures, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811121)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331112094.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.