Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHERN VENTURES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SOUTHERN VENTURES, INC. in 9843 TITAN COURT, A, LITTLETON, CO 80125 (NAICS 811121). OSHA activity number 331112094.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southern Ventures, INC. — free Get an email when a new federal OSHA severe-injury report for Southern Ventures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9843 TITAN COURT, A
City
LITTLETON
State
CO
ZIP
80125
Mailing
9843 TITAN COURT, A, LITTLETON, CO 80125
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
6
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 12, 2012
Abate by
May 24, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.134(c)(1):  A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) On or about February 7, 2012, and at times prior, the employees used respirators for spray painting activities without the employer providing a respiratory protection program.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.134 K06

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 12, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a)  On or about February 7, 2012, and at times prior, employees voluntarily wore respirators for sanding tasks and the employer had not given them required information about voluntary respirator use.
Recent events (1)
  • — Z (S) $0

1910.244 A02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 12, 2012
Abate by
Apr 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(2)(iii): Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack:  (a)  On or about January 10, 2012, and at times prior, an employee was exposed to crushing hazards while used a hydraulic jack to lift a vehicle and did not secure the vehicle in the lifted position.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2012
Abate by
Apr 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a)  On or about January 10, 2012, and at times prior, employees were exposed to shock and burn hazards from an extension cord in use with a welder where the insulation was pulled back from the plug.
Recent events (1)
  • — Z (S) $0

1910.333 B02 III A

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed:    (a)  On or about February 7, 2012, and at times prior an employee did not apply a positive means of locking out a light circuit before replacing light ballasts throughout the garage.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
Apr 12, 2012
Abate by
Apr 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) On or about January 10, 2012 and at times prior, electrical boxes on the north wall of the garage were blocked.
Recent events (1)
  • — Z (O) $0

View Southern Ventures, INC.'s full OSHA safety record →