Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: ENGINEERED PLASTIC COMPONENTS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ENGINEERED PLASTIC COMPONENTS, INC. in 300 SHELLHOUSE DRIVE, RANTOUL, IL 61866 (NAICS 326199). OSHA activity number 331112326.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Engineered Plastic Components, INC. for free Get an email when a new federal OSHA severe-injury report for Engineered Plastic Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 SHELLHOUSE DRIVE
City
RANTOUL
State
IL
ZIP
61866
Mailing
300 SHELLHOUSE DRIVE, RANTOUL, IL 61866
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
63
Ownership type
Private (A)

5 citations on file for this inspection.

1910.157 E02

Serious Gravity 5 1 instance 63 exposed
Issued
Feb 22, 2012
Abate by
Feb 23, 2012
Penalty
Initial $3,400 · Current $2,125 Reduced
29 CFR 1910.157(e)(2):     Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.    Engineered Plastic Components, Inc. had portable fire extinguishers within their facility for employee use in the event of a fire.  The company did not perform monthly visual inspections of the portable fire extinguishers to ensure that they were fully charged, undamaged, and ready for immediate employee use.
Recent events (2)
  • · I (S) $2125
  • · Z (S) $3400

1910.157 G01

Serious Gravity 5 63 instances 63 exposed
Issued
Feb 22, 2012
Abate by
Feb 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1):     Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.    Engineered Plastic Components, Inc. had portable fire extinguishers within their facility for employee use in the event of a fire.  The company did not provide an educational program to employees, in order to familiarize employees with the general principles of fire extinguisher use and the hazards associated with incipient stage fire fighting.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 22, 2012
Penalty
Initial $4,250 · Current $1,700 Reduced
29 CFR 1910.178(l)(1)(i):     The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    Engineered Plastic Components, Inc.  had employees operate powered industrial trucks on a daily basis without providing the employees with forklift training and evaluation.  This training would include:    a.	Formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material),  b.	Practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and   c.	Evaluation of the operators performance in the workplace.
Recent events (2)
  • · I (S) $1700
  • · Z (S) $4250

1910.178 L06

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 22, 2012
Abate by
Feb 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):     Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.    Engineered Plastic Components, Inc.  had employees operating powered industrial trucks, and the employer did not provide each forklift operator with a training and evaluation certification.   The certification would include the following:     a.	Name of the operator,   b.	Date of the training,   c.	Date of the evaluation, and   d.	Identity of the person(s) performing the training or evaluation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 22, 2012
Abate by
Feb 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7):     Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected.    Engineered Plastic Components, Inc.  had employees operating powered industrial trucks daily and on multiple shifts at the facility, and the employer did not institute a forklift inspection program.  This inspection program would include:    a.	Daily forklift inspections and/or  b.	Shift forklift inspections for those used on a round-the-clock basis.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Engineered Plastic Components, INC.'s full OSHA safety record →