NAPLES, ID —
OSHA Inspection: QUALITY FENCING & CONSTRUCTION INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of QUALITY FENCING & CONSTRUCTION INC in HWY 95, NAPLES, ID 83847 (NAICS 332311). OSHA activity number 331113332.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY FENCING & CONSTRUCTION INC
- Site address
- HWY 95
- City
- NAPLES
- State
- ID
- ZIP
- 83847
- Mailing
- 3774 HIGHWAY 6, PRINCETON, ID 83857
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332311
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.28 A
- Issued
- Mar 5, 2012
- Abate by
- Feb 13, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of approriate personal protective equipment in all operations where there was an exposure for hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to employees. (a) Southside greenhouse structure, off Hwy 95, Naples, Idaho: On or about January 10, 2012, and at times prior thereto, an employee was observed utilizing a screw gun and not utilizing safety glasses. (b) DELETED in ISA Note: Abatement certification IS NOT required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $1800
1926.501 B10
- Issued
- Mar 5, 2012
- Abate by
- Mar 6, 2012
- Penalty
- Initial $2,400 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section,each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrailsystem, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. (a) Southside of the property off Hwy 95, Naples, Idaho: On or about January 10, 2012, employees were observed not utilizing any means of fall protection while installing a metal roof onto a wood framed structure. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $2400
1926.1053 B13
- Issued
- Mar 5, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step. (a) Southside of the property, off Hwy 95, Naples, Idaho: An employee(s) was observed utilizing the top step of a stepladder as his means to access/egress a roof structure while performing roofing activities. Note: Abatement certification IS NOT required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.1053 B01
- Issued
- Mar 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support. (a) An employee was observed utilizing an extension ladder to access a roof structure and it did not extend at least three feet above the landing and it was not secured to prevent potential displacement. Note: Abatement certification IS NOT required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A01 III
- Issued
- Mar 5, 2012
- Abate by
- Mar 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee had been trained by a competent person on the proper construction, use, placement, and care in handling of all stairways and ladders. (a) On or about January 10, 2012, and at times prior thereto, employees were unable to recognize hazards related to ladders and were not equipped with the knowledge of the procedures to be followed to minimize hazards associated with using the top or top step of a stepladder as a working platform. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Quality Fencing & Construction INC
View Quality Fencing & Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 332311)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331113332.