Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: U.S. DEPT OF VETERANS AFFAIRS - VA HOSP W LOS ANGELES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of U.S. DEPT OF VETERANS AFFAIRS - VA HOSP W LOS ANGELES in 11301 WILSHIRE BLVD BLDG. 500 MICROBIOLOGY LAB, LOS ANGELES, CA 90073 (NAICS 622110). OSHA activity number 331113480.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept of Veterans Affairs - VA Hosp W LOS Angeles for free Get an email when a new federal OSHA severe-injury report for U.S. Dept of Veterans Affairs - VA Hosp W LOS Angeles is published. One employer, no account, unsubscribe in one click.
Site address
11301 WILSHIRE BLVD BLDG. 500 MICROBIOLOGY LAB
City
LOS ANGELES
State
CA
ZIP
90073
Mailing
11301 WILSHIRE BLVD, LOS ANGELES, CA 90073
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
3000
Ownership type
Federal government (D)

5 citations on file for this inspection.

1910.134 E01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 24, 2012
Abate by
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) At Bldg. 500 Microbiology Lab - On or about 12/27/11,  employees were not provided a medical clearance before being fit tested or required to use an N-95 respirator.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 F

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 24, 2012
Abate by
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f):     The employee was required to use a respirator without being fit tested with the same make, model, style and size of respirator that was to be used:    (a) At Bldg. 500, Microbiology Laboratory - On or about 12/27/11, some employees were not fit tested prior to requirement of N-95 respirator use.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.176 C

Serious Gravity 5 1 instance 15 exposed
Issued
May 24, 2012
Abate by
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.176(c):     Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:    (a) At Bldg. 500, Anaerobic Microbiology Laboratory - On or about 1/18/12, boxes that were stored on the floor in the aisle posed tripping hazards to employees.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 1 exposed
Issued
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii):     The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    (a) At Bldg. 94, microbiology lab entry hallway - On or about 1/18/12, the area immediately in front of two electrical panels was used for the storage of a recycling bin and storage rack.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1960.8 A

Serious Gravity 5 1 instance 15 exposed
Issued
May 24, 2012
Abate by
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1960.8(a):     The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to mycotoxins from mold in the microbiology laboratory:    (a) At Bldg. 500, Microbiology Lab - On or about 1/12/12, and at times prior thereto, the employer did not provide a place of employment free from the recognized hazard of mycotoxins from mold, which are likely to cause serious physical harm to employees. Employees had developed respiratory illness including allergies and persistent and worsening asthma with continued exposure to these specific strains of mold (Cladosporium, Penicillium, Aspergillus, Alternaria, and Fusarium). Feasible and acceptable means of abatement include but are not limited to: a) Eliminate water intrusion through the roof and ceiling;    (b) Regular inspection and maintenance of refrigerator to identify and repair drips and leaks;   (c) Regular cleaning of refrigerator surfaces to prevent excessive mold growth;   (d) Regular cleaning of laboratory floors to minimize disturbance of mold spores from foot traffic;   (e) Using air purifiers with HEPA;   (f) Using a mold remediation company to sanitize the refrigerator, as needed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331113480.