On , OSHA opened a complaint safety inspection of WRAYCO INDUSTRIES, INC. in 858 SEASONS ROAD, STOW, OH 44224 (NAICS 332312). OSHA activity number 331113605.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WRAYCO INDUSTRIES, INC.
- Site address
- 858 SEASONS ROAD
- City
- STOW
- State
- OH
- ZIP
- 44224
- Mailing
- 858 SEASONS ROAD, STOW, OH 44224
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 179
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 17, 2012
- Abate by
- May 1, 2012
- Penalty
- Initial $5,400 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: Automatic paint booth: Employees were exposed to a 61 1/2 inch fall while working on the platform doing powder coating operations.
Recent events (2)
- — I (S) $2970
- — Z (S) $5400
1910.23 D01
- Issued
- Apr 17, 2012
- Penalty
- Initial $2,700 · Current $1,485 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: The steps leading up to the spray booth which had six risers, did not have a standard railing on both sides of the steps.
Recent events (2)
- — I (S) $1485
- — Z (S) $2700
1910.24 B
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $4,500 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: Blow off area: Fixed stairs were not provided for employees who have to step over the blowers to enter the blow off area to blow water off the parts.
Recent events (2)
- — I (S) $2475
- — Z (S) $4500
1910.147 C01
- Issued
- Apr 17, 2012
- Abate by
- May 30, 2012
- Penalty
- Initial $3,600 · Current $1,980 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The company did not establish a program to protect employees involved with servicing and maintenance of machines and equipment from the unexpected energizing, start up, or release of stored energy. Energy sources included, but are not limited to, electrical, pneumatic, hydraulic, etc. The company maintains and services equipment such as, but not limited to, presses, press brakes, ovens, saws, shears, etc.
Recent events (2)
- — I (S) $1980
- — Z (S) $3600
1910.157 G02
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $2,700 · Current $1,485 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: The employer did not train employees on the use of portable fire extinguishers for those employees expected to fight incipient stage fires. NOTE: The employer may exercise one of the following options: 1) Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest extinguisher for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as required in 29 CFR 1910.157(g). The other sections of 29 CFR 1910.157 also apply. 2) Provide extinguishers as specified in 29 CFR 1910.157(c) (1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(c) and train/educate designated employees per 1910.157(g). Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3) Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy includes an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and (b). Utilizing this option exempts the employer from the requirements of 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 relating to use/storage of flammable/combustible liquids). If extinguishers are provided but not intended for employee use, 29 CFR 1910.157(a) and (f) are still applicable (inspection, maintenance and testing of equipment).
Recent events (2)
- — I (S) $1485
- — Z (S) $2700
1910.212 A01
- Issued
- Apr 17, 2012
- Penalty
- Initial $4,500 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by point of operation, in-going nip points, rotating parts, flying chips and sparks: (a) The MCH-FOO CNC, had no interlock; (b) Hatichi CNC had no interlock;
Recent events (2)
- — I (S) $2475
- — Z (S) $4500
1910.212 A03 II
- Issued
- Apr 17, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $6,300 · Current $3,465 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) The Niagara shear, operated by foot pedal, was not adequately guarded. The guard had an opening that measured approximately 3 inches. The following press brakes, operated by foot pedal, did not have any point of operation guarding: (1) Cincinnati 90 (2) Cincinnati 230T (#1) (3) Cincinnati 230T (#2) (4) LVD 360T (5) Cincinnati #STBC003 (6) Cincinnati #STBC004 (7) LVD 350 B#10 (8) LVD 175, S/N 15475
Recent events (2)
- — I (S) $3465
- — Z (S) $6300
1910.242 B
- Issued
- Apr 17, 2012
- Abate by
- Apr 24, 2012
- Penalty
- Initial $3,600 · Current $1,980 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Compressed air used for cleaning purposes was not reduced to 30 p.s.i. Compressed air measured approximately 70 p.s.i.
Recent events (2)
- — I (S) $1980
- — Z (S) $3600
1910.255 B04
- Issued
- Apr 17, 2012
- Abate by
- May 1, 2012
- Penalty
- Initial $3,600 · Current $1,980 Reduced
General-duty citation text
29 CFR 1910.255(b)(4): All press welding machine operations, where there was a possibility of the operator's fingers being under the point of operation, were not effectively guarded by use of a device such as an electronic eye safety circuit, two hand controls or protection similar to that prescribed for punch press operation in 29 CFR 1910.217: The Taylor Winfield spot welder, operated by foot pedal, did not have any point of operation guarding. The opening measured approximately 2 1/2 inches.
Recent events (2)
- — I (S) $1980
- — Z (S) $3600
1910.303 B02
- Issued
- Apr 17, 2012
- Penalty
- Initial $2,700 · Current $1,485 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A junction box used to power a fan, was hanging from the ceiling.
Recent events (2)
- — I (S) $1485
- — Z (S) $2700
1910.305 B02
- Issued
- Apr 17, 2012
- Abate by
- Apr 24, 2012
- Penalty
- Initial $2,700 · Current $1,485 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: The electrical panel door for the MCH-FOO CNC machine was open and would not close.
Recent events (2)
- — I (S) $1485
- — Z (S) $2700
More inspections at Wrayco Industries, INC.
View Wrayco Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331113605.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.