CALDWELL, ID ·
OSHA Inspection: R.S.T., INC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of R.S.T., INC in 1418 E ELGIN ST, CALDWELL, ID 83605 (NAICS 484121). OSHA activity number 331898288.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R.S.T., INC
- Site address
- 1418 E ELGIN ST
- City
- CALDWELL
- State
- ID
- ZIP
- 83605
- Mailing
- 1418 E ELGIN ST, CALDWELL, ID 83605
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Records only (C)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 28
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 9, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is an entrance to a ramp, stairway, or fixed ladder. The railingwas not provided with a toeboard wherever, beneath the open sides, persons can pass: (a) Top of shop stairs: On 1/19/2012 and at times prior thereto, the standard railing for the stair landing was not equipped with an intermediate rail. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $893
- · Z (S) $1785
1910.23 C01 I
- Issued
- Apr 9, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1(i): The railing was not provided with a toeboard wherever, beneath the open sides, persons can pass: (a) Top of shop stairs: On 1/19/2012 and at times prior thereto, the standard railing was missing the toeboard component of a standard railing. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.23 D01 II
- Issued
- Apr 9, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1(ii): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: on stairways less than 44 inches wide having one side open, at least one stair railing on open side. (a) Shop stairs: On 1/19/2012 and at times prior thereto, the stairway was missing the intermediate rail component of a stair railing. Note: Abatement certification IS required for this item.