SYRACUSE, NY —
OSHA Inspection: CUMMINS NORTHEAST, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUMMINS NORTHEAST, LLC in 6193 EASTERN AVE., SYRACUSE, NY 13211 (NAICS 423830). OSHA activity number 331898445.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUMMINS NORTHEAST, LLC
- Site address
- 6193 EASTERN AVE.
- City
- SYRACUSE
- State
- NY
- ZIP
- 13211
- Mailing
- 6193 EASTERN AVE., SYRACUSE, NY 13211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 30
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.157 G02
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) At the establishment, on or about 1/17/12: Fire extinguisher training was not conducted at least annually in that the last training was conducted 11/27/06. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1910.212 A01
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) Rebuild Area, on or about 1/17/12: Rotating chuck on a Delta drill press was not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1910.244 A01 II
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.244(a)(1)(ii): Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means: a) In the shop, on or about 1/17/12: Six portable floor jacks had no rated load markings on them. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1910.303 B07 IV
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) Rebuild Area, on or about 1/17/12: The outer jacket on the power cord for the Delta drill press was worn, deteriorating and cracking in several areas, exposing conductors to damage. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1910.304 G05
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective: a) Warranty Parts Staging Room, on or about 1/17/12: A Dayton pedestal fan and a floor fan were not grounded in that the ground pins were missing from their plug ends. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Rebuild Area, on or about 1/17/12: Door used as an exit was not marked with an "Exit" sign. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Feb 6, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years: a) At the establishment, on or about 1/17/12: Evaluations of forklift operators was last conducted 10/2/07. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423830)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331898445.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.