SPRINGFIELD, OH ·
OSHA Inspection: KEYAH INTERNATIONAL TRADING LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KEYAH INTERNATIONAL TRADING LLC in 4655 URBANA RD, SPRINGFIELD, OH 45502 (NAICS 339991). OSHA activity number 331898635.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYAH INTERNATIONAL TRADING LLC
- Site address
- 4655 URBANA RD
- City
- SPRINGFIELD
- State
- OH
- ZIP
- 45502
- Mailing
- 4655 URBANA RD, SPRINGFIELD, OH 45502
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339991
- Employees
- 39
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 1, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) The written lockout program and procedures were inadequate in that they did not include tasks, such as, but not limited to, cleaning of the glue machine with exposure to accidental start-up and being cuaght in the nip points of the rollers as requiring lockout. (b) There were no documented procedures for equipment with multiple energy sources, such as, but not limited to, the Bruno presses, the Relco press and the baler to ensure the isolation of all energy sources. (c) The written program stated that tags alone could be used for lockout even though the machinery would accept locks.
Recent events (2)
- · I (S) $3500
- · Z (S) $3500
1910.147 C06 I
- Issued
- Feb 1, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) There had not been any periodic or at least annual inspections of the energy control (lockout) procedures performed with records kept.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
1910.147 C07 I
- Issued
- Feb 1, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) The glue machine operator and other operators were not trained as authorized employees to perform lockout during tasks, such as, but not limited to, cleaning operations, where exposed to accidental start up or activation of roller nip points on the glue machine.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
1910.147 D04 I
- Issued
- Feb 1, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On or about January 23, 2012, employee(s) who cleaned the glue machine, de-energized the machine but did not lock out the main power disconnect.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
1910.212 A01
- Issued
- Feb 1, 2012
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, rotating parts, etc.: (a) On or about January 14, 2012, the Black Brothers gluing machine (s/n 181130) was inadequately guarded as the hinged guard on the feed side was not secured in position and/or interlocked with the operating controls to stop the glue rolls in the event the guard is lifted out of position exposing the ingoing nip point of the top rolls.
Recent events (2)
- · I (S) $2500
- · Z (S) $5000
1910.332 B01
- Issued
- Feb 1, 2012
- Abate by
- May 15, 2012
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: (a) The maintenance employee(s) were inadequately trained and instructed on electrical safety related work practices and the appropriate protective equipment required when performing tasks such as trouble shooting and voltage testing up to 480 VAC.
Recent events (2)
- · I (S) $3500
- · Z (S) $3500
1910.333 A
- Issued
- Feb 1, 2012
- Abate by
- May 15, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: (a) On or about January 19, 2012, the maintenance employee performed trouble shooting/voltage testing on the 480 VAC on one of the Bruno presses and electrical safety-related work practices were not employed, such as the wearing of appropriate personal protective equipment when the task required electrical power to be present and could not be de-energized and locked out.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
1910.335 A01 I
- Issued
- Feb 1, 2012
- Abate by
- May 15, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: (a) On or about January 19, 2012 and prior to that time, the maintenance employee performed troubleshooting and voltage testing on 480 VAC and was not provided with and did not use appropriate personal protective equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
1910.147 C05 II D
- Issued
- Feb 1, 2012
- Abate by
- Feb 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices did not indicate the identity of the employee applying the device(s) (a) The Bruno press #1 was locked out with a red lockout lock that was marked and the tag with it was not filled out as to who applied the lock.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 339991)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331898635.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.