MERRIMACK, NH —
OSHA Inspection: PALACE CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PALACE CONSTRUCTION, INC. in 80 PREMIUM OUTLETS BLVD., MERRIMACK, NH 03054 (NAICS 238160). OSHA activity number 331899088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALACE CONSTRUCTION, INC.
- Site address
- 80 PREMIUM OUTLETS BLVD.
- City
- MERRIMACK
- State
- NH
- ZIP
- 03054
- Mailing
- 12 COLBY RD., LITCHFIELD, NH 03052
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 29
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Jul 11, 2012
- Abate by
- Jul 12, 2012
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. Building 1,4- Employees working from the roof were not protected from falls of approximately 20 feet when fall protection was not used or provided.
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
1926.1051 A
- Issued
- Jul 11, 2012
- Abate by
- Jul 12, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a. Buildings 1,4- Employees climbing out of lift to access roofs of buildings 1 and 4 did not have adequate access where there was a break in elevation of 20 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.404 F06
- Issued
- Jul 11, 2012
- Abate by
- Jul 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a. Building 5- Employees were allowed to use an extension cord which was plugged into a GFCI protected electrical outlet for temporary power that was missing a ground pin.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Palace Construction, INC.
View Palace Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331899088.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.