WATERVILLE, NY ·
OSHA Inspection: PUMILIA'S PIZZA SHELLS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PUMILIA'S PIZZA SHELLS INC. in 1594 ROUTE 315, WATERVILLE, NY 13480 (NAICS 311822). OSHA activity number 331899336.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PUMILIA'S PIZZA SHELLS INC.
- Site address
- 1594 ROUTE 315
- City
- WATERVILLE
- State
- NY
- ZIP
- 13480
- Mailing
- PO BOX 345, WATERVILLE, NY 13480
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311822
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.37 B02
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $1,800 · Current $550 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) On or about 1/20/2012, In the facility: None of the exit doors were labeled. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $550
- · C (S) $1800
- · Z (S) $1800
1910.157 C01
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not provided, mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about 1/20/2012, In the facility: There was no fire extinguisher in the facility, where Kerosene was being dispensed and used. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.147 C01
- Issued
- Mar 7, 2012
- Abate by
- Mar 28, 2012
- Penalty
- Initial $2,400 · Current $800 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 1/20/12, In the facility. Employees were required to clean equipment such as the CAM Horizontal Dough Mixer, Rondo Sheeter and Dough Divider. The company had not developed and implemented a lock out program to control energy. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $800
- · C (S) $2400
- · Z (S) $2400
1910.212 A05
- Issued
- Mar 7, 2012
- Abate by
- Mar 28, 2012
- Penalty
- Initial $2,400 · Current $800 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) On or about 1/20/12, In the facility: A two and a half foot diameter fan was being used that had no guard on one side and openings of over twelve inches on the other side. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $800
- · C (S) $2400
- · Z (S) $2400
1910.219 C04
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $2,400 · Current $800 Reduced
General-duty citation text
29 CFR 1910.219(c)(4): Projecting shaft ends did not present a smooth edge and end: a) On or about 1/20/12, In the facility: A one inch diameter shaft with an open keyway projected three inches. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $800
- · C (S) $2400
- · Z (S) $2400
1910.263 C03
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.263(c)(3): Sprocket(s) and V-belt drive(s) of bakery machinery located within reach from platform(s) or passageway(s) or located within 8 feet 6 inches from the floor were not completely enclosed: a) On or about 1/20/12, In the facility: A V belt pulley on the Rondo Sheeter was not guarded. b) On or about 1/20/12, In the facility: A six inch and a four inch sprocket the sheet conveyor was not guarded. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.263 E01 V
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $2,400 · Current $800 Reduced
General-duty citation text
29 CFR 1910.263(e)(1)(v): All mixers with power and manual dumping arrangements were not equipped with safety devices which shall: Engage both hands of the operator when the agitator is in motion under power, and while the bowl is open more than one fifth of its total opening. Prevent the agitator from being started, while the bowl is opened more than one fifth open, without engaging both hands of the operator. a) On or about 1/20/12, In the facility: A CAM Industries mixer, Model MS34-3 was not equipped with a two handed jog button. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $800
- · C (S) $2400
- · Z (S) $2400
1910.263 E01 VIII
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.263(e)(1)(viii): Every mixer shall be equipped with a full enclosure over the bowl which is closed at all timeswhile the agitator is in motion. Only minor openings in this enclosure, such as ingredient doors, flour inlets, etc., each representing less than 11/2 square feet in area, shall be capable of being opened while the mixer is in operation. a) On or about 1/20/12, In the facility: A CAM Industries mixer, Model MS34-3 was not equipped with a cover interlock. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.303 G02 I
- Issued
- Mar 7, 2012
- Abate by
- Mar 21, 2012
- Penalty
- Initial $3,000 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about 1/20/12, In the facility: A cover was removed off of a Rondo Sheet Roller, exposing energized parts. b) On or about 1/20/12, In the facility, South West Wall: Breakers were missing inside of a panel box, exposing energized parts. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $1250
- · C (S) $3000
- · Z (S) $3000
More inspections in this industry (NAICS 311822)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331899336.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.