Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: DEERE & COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEERE & COMPANY in 909 RIVER RD, MOLINE, IL 61265 (NAICS 333111). OSHA activity number 331901207.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deere & Company for free Get an email when a new federal OSHA severe-injury report for Deere & Company is published. One employer, no account, unsubscribe in one click.
Establishment
DEERE & COMPANY
Site address
909 RIVER RD
City
MOLINE
State
IL
ZIP
61265
Mailing
ATTN: TRAVIS DROESSLER 501 RIVER DRIVE, MOLINE, IL 61265
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Case closed
Last modified
Data loaded
NAICS code
333111
Employees
300
Ownership type
Private (A)

5 citations on file for this inspection.

1910.23 A07

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2012
Abate by
May 3, 2012
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.23(a)(7):     Every temporary floor opening did not have standard railings, or was not constantly attended by someone:    Employees working on and around the 96 Plater were exposed to falling into the sump pit under the plater because grating was removed and the floor opening did not have a guardrail and the floor hole was not constantly attended.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $5000

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2012
Abate by
May 3, 2012
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    Employees working on top of the C261 Okuma in Department 180 performing maintenance were exposed to falling approximately 7 feet, 7 inches from the top of the machine to the concrete floor because suitable fall protection was not provided.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $5000

1910.147 C06 I C

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2012
Abate by
Aug 17, 2012
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.147(c)(6)(i)(C):     Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:    Employees were exposed to hazardous energy when performing servicing and maintenance tasks on the employer's machinery and the periodic inspection did not include a review of the energy control procedures with each authorized employee.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $5000

1910.147 C06 II

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2012
Abate by
Aug 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:    Employees were exposed to hazardous energy when performing servicing and maintenance task because the employer did not document periodic inspections and record the identification of the machine or equipment, inspection date, names of the employees included in the inspection and the name of the person performing the inspection.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
May 2, 2012
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i):     Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    Employees working in and around the Department 125 conference room were exposed to electrical hazards because the light switch box did not have a cover.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4000

View Deere & Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331901207.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.