HIGHLAND PARK, IL ·
OSHA Inspection: RIGHT DONE CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIGHT DONE CORPORATION in 100 SHERIDAN RD., HIGHLAND PARK, IL 60035 (NAICS 238350). OSHA activity number 331901272.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIGHT DONE CORPORATION
- Site address
- 100 SHERIDAN RD.
- City
- HIGHLAND PARK
- State
- IL
- ZIP
- 60035
- Mailing
- 830 E. OLD WILLOW RD., PROSPECT HEIGHTS, IL 60070
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Feb 9, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $4,200 · Current $1,780 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels was not fully planked or decked between front uprights and the guardrail supports: a) Employees were exposed to fall hazards of approximately 16.5 feet while working on scaffold platforms which were not fully decked. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1780
- · Z (S) $4200
1926.451 G01
- Issued
- Feb 9, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: a) Employees working from frame scaffolding were exposed to fall hazards of approximately 16.5 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B13
- Issued
- Feb 9, 2012
- Penalty
- Initial $4,200 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Employees performing carpentry work were exposed to fall hazards of approximately 19 feet. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $1680
- · Z (S) $4200
1926.1053 B04
- Issued
- Feb 9, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $2,400 · Current $1,040 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Employees were exposed to fall hazards while using an a-frame ladder which was not unfolded. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1040
- · Z (S) $2400
1926.405 G01 III
- Issued
- Feb 9, 2012
- Abate by
- Feb 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(1)(iii): Flexible cords and cables were: (A) Used as a substitute for the fixed wiring of a structure; (B) Run though holes in walls, ceilings, or floors; (C) Run through doorways, windows, or similar openings; (D) Attached to building surfaces; or (E) Concealed behind building walls, ceilings, or floors: a) Flexible cords and cables were run though windows. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).