CARROLL, OH —
OSHA Inspection: KIRK BROTHERS MASONRY, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of KIRK BROTHERS MASONRY, INC. in 5240 PLUM ROAD, CARROLL, OH 43112 (NAICS 238140). OSHA activity number 331901439.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KIRK BROTHERS MASONRY, INC.
- Site address
- 5240 PLUM ROAD
- City
- CARROLL
- State
- OH
- ZIP
- 43112
- Mailing
- 11942 US HIGHWAY 224, ALVADA, OH 44802
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 C01 II
- Issued
- Feb 29, 2012
- Abate by
- Mar 7, 2012
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1m) or less there after for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less there after for scaffolds greater than 3 feet (0.91m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other). At the worksite, the employer did not ensure/enforce that the 105 foot long, 5 to 6 buck high tubular welded scaffold was tied and braced at intervals not to exceed 30 feet, thereby exposing employees to approximate 36 foot fall hazard.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1926.451 G01
- Issued
- Feb 29, 2012
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs,and other elevated surfaces are set forth in subpart M of this part. At the worksite, the employer did not ensure/enforce that the tubular welded scaffold was guarded by the stack of block that was being transferred by an employee to the block layers that were building the NE wall of the gymnasium, thereby exposing the employee to approximate 36 foot fall hazard.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
More inspections at Kirk Brothers Masonry, INC.
View Kirk Brothers Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331901439.