OSHA Inspection: A DIAMOND GLASS OF CHICAGO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A DIAMOND GLASS OF CHICAGO, INC. in 658 OAKLEY BLVD, CHICAGO, IL 60612 (NAICS 238350). OSHA activity number 331901694.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A Diamond Glass of Chicago, INC. for free Get an email when a new federal OSHA severe-injury report for A Diamond Glass of Chicago, INC. is published. One employer, no account, unsubscribe in one click.
Site address
658 OAKLEY BLVD
City
CHICAGO
State
IL
ZIP
60612
Mailing
1801 N. HUMBOLDT BLVD, CHICAGO, IL 60647
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
6
Ownership type
Private (A)

5 citations on file for this inspection.

1926.405 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 8, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1926.405(g)(2)(iii): Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hardservice flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usagecharacteristics of the cord being spliced.    a.  On or about January 26, 2012 - at the above addressed jobsite, a flexible cord with visible splices was used to power electrical tools such as a chop saw and a battery charger, thereby exposing the employees to hazards associated with electrical shock.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800

1926.416 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.    On or about January 26, 2012 - at the above addressed jobsite, a frayed electric cord was used to power electrical tools such as a chop saw and a battery charger, thereby exposing the employees to hazards associated with electrical shock.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B14

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 8, 2012
Abate by
Feb 9, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.501(b)(14): "Wall openings." Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safetynet system, or a personal fall arrest system.    a.  On or about January 26, 2012 - at the above addressed jobsite, employees conducting window frame installation were exposed to falls of approximately nineteen (19) feet, four (4) inches created by the presence of a wall opening.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $4200

1926.1053 B04

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 8, 2012
Abate by
Feb 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.    a.  On or about January 26, 2012 - at the above addressed jobsite, an employee was partially standing on a six (6) foot A frame ladder, thereby exposing the employee to a fall hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1052 C01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 8, 2012
Abate by
Feb 9, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with at least one handrail.    a.  On or about January 26, 2012 - at the above addressed jobsite, employees were exposed to an unprotected stairway, thereby exposing employees to fall hazards.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800