Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: READY MIX CONCRETE CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of READY MIX CONCRETE CO. in 6200 CORNHUSKER HIGHWAY, LINCOLN, NE 68529 (NAICS 327320). OSHA activity number 331902973.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ready MIX Concrete CO. — free Get an email when a new federal OSHA severe-injury report for Ready MIX Concrete CO. is published. One employer, no account, unsubscribe in one click.
Site address
6200 CORNHUSKER HIGHWAY
City
LINCOLN
State
NE
ZIP
68529
Mailing
6200 CORNHUSKER HIGHWAY, LINCOLN, NE 68529
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
72
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2012
Abate by
Mar 5, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    Throughout the Facility:  The employer has failed to ensure that employees are utilizing specific procedures for the control of potentially hazardous energy while engaged in activities requiring lockout/tag out.  The company has developed procedures but has failed to ensure their use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 C04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2012
Abate by
Mar 5, 2012
Penalty
Initial $0 · Current $4,900
29 CFR 1910.147(c)(4)(ii):     Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h):    Thorughout the Company:  The employer has failed to develop procedures/methods that include a means to enforce the failure to utilize lockout/tag out specific procedures.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $0

1910.334 A04

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2012
Abate by
Feb 27, 2012
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.334(a)(4):     Conductive work locations. Portable electric equipment and flexible cords used in highly conductive work locations (such a those inundated with water or other conductive liquids), or in job locations where employees are likely to contact water or conductive liquids,shall be approved for those locations.    Jobsite located at 6200 Cornhusker Highway, Lincoln NE; product conveyor tunnel:  On January 11, 2012, an employee sustained an electrical shock while working in the vicinity of an energized portable grinder and extension cord that had come into contact with water.  The employee was working on a de-energized conveyor motor when he came into contact with the electrical current.  Neither the grinder nor the extension cord was rated for use in wet locations.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 C06 I

Repeat Gravity 10 1 instance 2 exposed
Issued
Feb 3, 2012
Abate by
Mar 16, 2012
Penalty
Initial $35,000 · Current $17,500 Reduced
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    Throughout the Facility:  The employer failed to conduct a periodic inspection of the energy control procedures as outlined in the standard.  The employer did conduct a limited number of reviews for some of the procedures but failed to review each procedure.      NEBCO, Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(c)(6)(i), which was contained in  OSHA inspection number 311463228, Citation #1, Item #1, and became a final order on October 14, 2008.
Recent events (2)
  • — I (R) $17500
  • — Z (R) $35000

View Ready MIX Concrete CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331902973.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.