WHEELING, IL —
OSHA Inspection: DURABLE INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of DURABLE INC. in 750 NORTHGATE PARKWAY, WHEELING, IL 60090 (NAICS 332999). OSHA activity number 331904292.
Where did this inspection happen?
- Establishment
- DURABLE INC.
- Site address
- 750 NORTHGATE PARKWAY
- City
- WHEELING
- State
- IL
- ZIP
- 60090
- Mailing
- 750 NORTHGATE PARKWAY, WHEELING, IL 60090
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 300
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1000 A02
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
C730
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of carbon monoxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 50 parts per million (ppm): Durable Inc. - The employer did not ensure employees were not exposed to a concentration(s) of carbon monoxide in excess of the OSHA Permissible Exposure Limit of 50 parts per million (ppm) as an 8 hour Time Weighted Average Concentration. a) Durable Inc. - On January 31, 2012, an employee was exposed to a concentration of carbon monoxide of 84.9 parts per million (ppm). This is in excess of and is 1.64 times the OSHA acceptable Time Weighted Average (TWA) of 50 ppm listed in Table Z-1. The exposure was measured over 300 minutes. Zero exposure was assumed for a period of 180 minutes. The carbon monoxide permissible exposure limit is established to prevent headaches, nausea, unconsciousness and asphyxiation. The measured occupational exposure to carbon monoxide is based on post-exposure employee carboxyhemoglobin measurements. b) Durable Inc. - On January 31, 2012, an employee was exposed to a concentration of carbon monoxide of 130 ppm. This is in excess of and is 2.6 times the OSHA acceptable Time Weighted Average (TWA) of 50 ppm listed in Table Z-1. The exposure was measured over 296 minutes. Zero exposure was assumed for a period of 184 minutes. The carbon monoxide permissible exposure limit is established to prevent headaches, nausea, unconsciousness and asphyxiation. The measured occupational exposure to carbon monoxide is based on post-exposure employee carboxyhemoglobin measurements. c) Durable Inc. - On January 31, 2012, an employee was exposed to a concentration of carbon monoxide of 121.7 ppm. This is in excess of and is 2.43 times over the OSHA acceptable Time Weighted Average (TWA) of 50 ppm listed in Table Z-1. The exposure was measured over 300 minutes. Zero exposure was assumed for a period of 180 minutes. The carbon monoxide permissible exposure limit is established to prevent headaches, nausea, unconsciousness and asphyxiation. The measured occupational exposure to carbon monoxide is based on post-exposure employee carboxyhemoglobin measurements. d) Durable Inc. - On January 31, 2012 an employee was exposed to a concentration of carbon monoxide of 61.0 ppm. This is 1.22 times over the OSHA acceptable Time Weighted Average (TWA) of 50 ppm listed in Table Z-1. The exposure was measured over 300 minutes. Zero exposure was assumed for a period of 180 minutes. The carbon monoxide permissible exposure limit is established to prevent headaches, nausea, unconsciousness and asphyxiation. The measured occupational exposure to carbon monoxide is based on post-exposure employee carboxyhemoglobin measurements.
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.1000 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
C730
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined or implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d). a) Durable Inc. - Effective engineering and administrative controls were not instituted and maintained by the employer to reduce employee exposure to carbon monoxide during maintenance of heating equipment, including, but not limited to: 1) Seek the expertise of a competent individual such as an engineer or certified industrial hygienist to assess the existing controls for exhaust and combustion gases from heating units used at the site, including ventilation, and implement appropriate modifications. 2) Replace or repair the deteriorated gas utilization equipment, such as heaters, in the facility. Ensure new equipment is installed and operated according to the manufacturer's specifications and all national, state and local codes. 3) Provide combustion and ventilation air for all appliances located within the space as required by the overhead heater manufacturer and the National Fire Protection Association (NFPA) 54, National Fuel Gas Code to ensure proper venting of combustion and ensure safe working conditions for personnel. 4) Provide for the inspection of all overhead heater(s) located within the work site at intervals required by the heater manufacturer. Step 1 A written detailed plan of abatement shall be submitted to the Area Director outlining a schedule for implication of engineering and or administrative measures to control employee exposures to carbon monoxide from the overhead heaters. The plan shall include, at a minimum, target dates for the following actions which must be consistent with the dates required by the citation. 1) Evaluation of engineering/administration control options; 2) Selection of optimum control methods and completion of design; 3) Procurement, installation and operation of selected control measures; 4) Testing and acceptance of control methods. All control methods shall be evaluated for each particular use by a technically qualified person. Abatement Date: July 24, 2012 Step 2 Abatement shall been completed by the implementation of feasible engineering controls and verification of their effectiveness in achieving compliance. Abatement Date: August 22, 2012
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at DURABLE INC.
WHEELING, IL—2020-05-22 00:00:00
DURABLE INC.
WHEELING, IL—2006-07-11 00:00:00
DURABLE, INC.
WHEELING, IL—2004-04-07 00:00:00
DURABLE, INC.
EAST LAKE, MI—1991-04-01 00:00:00
DURABLE INC.
View DURABLE INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
SMITHFIELD, UT—2026-07-16
METAL VISION INC.
MINNEAPOLIS, MN—2026-07-15
111597 - CHANDLER INDUSTRIES INC - BLAINE DIVISION
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331904292.