BROOKLYN, NY —
OSHA Inspection: NAYA CONSTRUCTION, CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NAYA CONSTRUCTION, CORP. in 2317 OCEAN PARKWAY, BROOKLYN, NY 11223 (NAICS 236116). OSHA activity number 331905679.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAYA CONSTRUCTION, CORP.
- Site address
- 2317 OCEAN PARKWAY
- City
- BROOKLYN
- State
- NY
- ZIP
- 11223
- Mailing
- 2526 CONEY ISLAND AVE., BROOKLYN, NY 11223
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.405 J01
- Issued
- May 29, 2012
- Abate by
- Jun 5, 2012
- Penalty
- Initial $3,300 · Current $3,300
General-duty citation text
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles had live parts exposed to employee contact. a) 1st floor, east side: Employees connected temporary wiring for lamps to a pair of outlets for lighting. The pair of electrical receptacles were spliced to a temporary flexible cord and were not installed in a enclosure. On or about 01/26/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3300
1926.405 J01 II
- Issued
- May 29, 2012
- Abate by
- Jun 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, and receptacles were not securely supported. a) 1st floor, east side: Employees connected temporary wiring for lamps to a pair of outlets for lighting. The pair of electrical receptacles were spliced to a temporary flexible cord and were not installed in a enclosure. On or about 01/26/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1926.404 B01 I
- Issued
- May 29, 2012
- Penalty
- Initial $3,300 · Current $3,300
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified inparagraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section toprotect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) 1st floor, east side: Employees used an electric powered chop saw to do carpentry work. The chop saw was connected to an extension cord, which was routed to a nearby outlet device and was not provided with a ground fault circuit interrupter. On or about 01/26/12. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3300
1926.1052 C12
- Issued
- May 29, 2012
- Penalty
- Initial $3,300 · Current $3,300
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings shall be provided with guardrail systems.Guardrail system criteria are contained in subpart M of this part.[55 FR 47687, Nov. 14, 1990; 56 FR 47689, Jan. 23, 1991; 56 FR 41794, Aug. 23, 1991] a) 1st floor, east side: Employees walked and worked at unprotected edges of a stairway landing, which leads to the basement. Guardrails systems were not installed at the unprotected edges of the stairway landing. On or about 01/23/12. b) 2nd floor, west side: Employees walked and worked at unprotected edges of a stairway landing, which leads to the 1st floor. Guardrails systems were not installed at the unprotected edges of the stairway landing. On or about 01/23/12. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3300
1926.501 B01
- Issued
- May 29, 2012
- Penalty
- Initial $9,240 · Current $9,240
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level wsa not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) House 3rd floor, south side: Two employees walked and worked on 3rd floor joists at an unprotected edge without fall protection. On or about 01/23/12. b) House 2nd floor, west side: Employees walk and worked at an unprotected edge without fall protection. On or about 01/23/12. Naya Construction Corp. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.501(b)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314169525, CITATION NUMBER 1, ITEM NUMBER 3, ISSUED ON 06/25/2010 WITH A FINAL ORDER DATE OF 12/20/2010. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (R) $9240
1926.503 A01
- Issued
- May 29, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $5,280 · Current $5,280
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fallhazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed inorder to minimize these hazards. a) Jobsite: The employer did not provide fall protection training to employees who were exposed to fall hazards, including but not limited to: walking and working at unprotected edges on the 2nd and 3rd floor without fall protection. On or about 01/23/12. 1st REPEAT Naya Construction Corp WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.503(a)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314169525, CITATION NUMBER 1, ITEM NUMBER 4a, ISSUED ON 06/25/2010 WITH A FINAL ORDER DATE OF 12/20/2010. NOTE: IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
- — Z (R) $5280
More inspections at Naya Construction, Corp.
View Naya Construction, Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331905679.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.