CHICAGO, IL ·
OSHA Inspection: ANDREW FUDALA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANDREW FUDALA in 10222 S. WESTERN AVE, CHICAGO, IL 60643 (NAICS 238140). OSHA activity number 331906180.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANDREW FUDALA
- Site address
- 10222 S. WESTERN AVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60643
- Mailing
- 903 EAST STREET, LEMONT, IL 60439
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.451 G01
- Issued
- Feb 17, 2012
- Penalty
- Initial $4,200 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. a. On or about January 25, 2012 - at the above addressed jobsite, an employee standing on the top section of a tubular welded frame scaffold, approximately fourteen (14') feet, three (3") inches above the ground, was exposed to injuries from falls due to the lack of a complete guardrail system. b. On or about January 25, 2012 - at the above addressed jobsite, an employee conducting brick laying operation on the outrigger section of a the tubular welded frame scaffold, approximately ten (10') feet, seven (7") inches above the ground, was exposed to injuries from falls due to the lack of side of guardrails. c. On or about January 25, 2012 - at the above addressed jobsite, employees conducting brick laying operations on the outrigger section of a tubular welded frame scaffold, approximately ten (10') feet, seven (7") inches above the ground, were exposed to injuries from falls due to the lack of back guardrails.
Recent events (2)
- · I (S) $2000
- · Z (S) $4200
More inspections in this industry (NAICS 238140)