FRANKLIN, OH —
OSHA Inspection: STILLWELL ROOFING, CO & CONST.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of STILLWELL ROOFING, CO & CONST. in 3707 GREY OWL COVE, FRANKLIN, OH 45005 (NAICS 238160). OSHA activity number 331906412.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STILLWELL ROOFING, CO & CONST.
- Site address
- 3707 GREY OWL COVE
- City
- FRANKLIN
- State
- OH
- ZIP
- 45005
- Mailing
- 1011 SETTLEMIRE RD., LEBANON, OH 45036
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Feb 15, 2012
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person. a) The employer did ensure that a competent person first conducted jobsite inspection to idenify fall hazards before roofing work started.
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
1926.501 B13
- Issued
- Feb 15, 2012
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) The employees engaged in removing existing roof shingles off a residential two story house with a 6 in 12 roof pitch section were not provided fall protection and were at the roof edge exposed to a 18 feet and greater fall hazard to the lower ground level.