SCOTIA, NY ·
OSHA Inspection: SPECIALTY QUALITY PACKAGING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPECIALTY QUALITY PACKAGING in 602 POTENTIAL PARKWAY, SCOTIA, NY 12302 (NAICS 322299). OSHA activity number 331908707.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECIALTY QUALITY PACKAGING
- Site address
- 602 POTENTIAL PARKWAY
- City
- SCOTIA
- State
- NY
- ZIP
- 12302
- Mailing
- 602 POTENTIAL PARKWAY, SCOTIA, NY 12302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- Employees
- 95
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.219 F01
- Issued
- Apr 6, 2012
- Penalty
- Initial $3,273 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a) Establishment, on or about 2/1/2012: Kidder Printer Machine, employees exposed to unguarded sprocket/gear assembly at the right rear of machine.
Recent events (2)
- · I (S) $1700
- · Z (S) $3272.5
1910.303 B02
- Issued
- Apr 6, 2012
- Penalty
- Initial $3,080 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Warehouse, on or about 2/01/2012: Cover for electrical panel LVP19 was not fully secured to the cabinet, exposing employees to shock and burn hazards as they used the breaker switches.
Recent events (2)
- · I (O) $0
- · Z (S) $3080
1910.151 C
- Issued
- Apr 6, 2012
- Abate by
- Apr 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Establishment, on or about 1/31/2012: Employees working with cleaning products and ink near the Kidder Printing Machine did not have a suitable eye wash station; eyewash was not maintained in operational and sanitary condition.
Recent events (2)
- · I (O) $0