ALBANY, NY ·
OSHA Inspection: CLEAR VIEW BAG COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLEAR VIEW BAG COMPANY, INC. in 5 BURDICK DRIVE, ALBANY, NY 12211 (NAICS 326113). OSHA activity number 331909382.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLEAR VIEW BAG COMPANY, INC.
- Site address
- 5 BURDICK DRIVE
- City
- ALBANY
- State
- NY
- ZIP
- 12211
- Mailing
- PO BOX 11160, ALBANY, NY 12211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326113
- Employees
- 80
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.179 J02
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $2,520 · Current $1,764 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard: On or about February 2, 2012, the following hoists are in use without frequent inspection as per the manufacturer's recommendations: (a) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # A9116409, Model 7756-ETA-010-CDD (b) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # SP220-0720-96, Model 7756E-2A10-C6 (c) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # D909 6635, Model 7756E-AA0-10-CDD (d) K2 Print Press - 1/2 ton Budgit air operated chain hoist Serial # 982627 (e) K2 Print Press - 1/2 ton Budgit air operated chain hoist Serial # 990560 (f) K2 Print Press - 1/2 ton Ingersoll-Rand air operated chain hoist Serial # SP414-0805-97, Model ML 1000K 2C10-C6 (g) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 583741 (h) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 5331455 (i) Soda Blast Room - 1/4 ton Coffing electric operated chain hoist Serial # 173N, Model EMW-500-B
Recent events (2)
- · I (S) $1764
- · Z (S) $2520
1910.179 J03
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: On or about February 2, 2012, the following hoists are in use without periodic inspection as per the manufacturer's recommendations: (a) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # A9116409, Model 7756-ETA-010-CDD (b) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # SP220-0720-96, Model 7756E-2A10-C6 (c) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # D909 6635, Model 7756E-AA0-10-CDD (d) K2 Print Press - 1/2 ton Budgit air operated chain hoist Serial # 982627 (e) K2 Print Press - 1/2 ton Budgit air operated chain hoist Serial # 990560 (f) K2 Print Press - 1/2 ton Ingersoll-Rand air operated chain hoist Serial # SP414-0805-97, Model ML 1000K 2C10-C6 (g) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 583741 (h) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 5331455 (i) Soda Blast Room - 1/4 ton Coffing electric operated chain hoist Serial # 173N, Model EMW-500-B
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.179 L01
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(1): A preventive maintenance program based on the crane manufacturer's recommendations was not established: On or about February 2, 2012, the following hoists are in use without a preventative maintenance program as per the manufacturer's recommendations: (a) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # A9116409, Model 7756-ETA-010-CDD (b) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # SP220-0720-96, Model 7756E-2A10-C6 (c) K1 Print Press - 1/2 ton ARO air operated chain hoist Serial # D909 6635, Model 7756E-AA0-10-CDD (d) K2 Print Press - 1/2 ton Budgit air operated chain hoist Serial # 982627 (e) K2 Print Press - 1/2 ton Budgit air operated chain hoist Serial # 990560 (f) K2 Print Press - 1/2 ton Ingersoll-Rand air operated chain hoist Serial # SP414-0805-97, Model ML 1000K 2C10-C6 (g) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 583741 (h) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 5331455 (i) Soda Blast Room - 1/4 ton Coffing electric operated chain hoist Serial # 173N, Model EMW-500-B
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Feb 24, 2012
- Abate by
- Mar 31, 2012
- Penalty
- Initial $4,410 · Current $3,090 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Printing Press Room - On or about February 2, 2012, the K1 Kidder Printing Press was used with inadequate guarding exposing employees to amputation hazards from in running nip points. b) Printing Press Room - On or about February 2, 2012, the K2 Kidder Printing Press was used with inadequate guarding exposing employees to amputation hazards from in running nip points. c) Production Room - On or about February 2, 2012, Ro-An Polystar 1500 #3 (Serial # 4669) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. d) Production Room - On or about February 2, 2012, Ro-An Polystar 1500 #4 (Serial # 4811) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. e) Production Room - On or about February 2, 2012, Ro-An Polystar 9350 #5 (Serial # 6248-07) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. f) Production Room - On or about February 2, 2012, Ro-An Polystar 9450 #6 was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. g) Production Room - On or about February 2, 2012, Ro-An Polystar 6000 #7 (Serial # 4338) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. h) Production Room - On or about February 2, 2012, Ro-An Polystar 9500 #8 (Serial # 5284-98) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. i) Production Room - On or about February 2, 2012, Ro-An Polystar 9500HS #9 (Serial # 5497-00) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points. j) Production Room - On or about February 2, 2012, Ro-An Polystar 4500 #15 (Serial # 5721-01) was in use with guards that were not securely affixed exposing employees to amputation hazards from in running nip points.
Recent events (2)
- · I (S) $3090
- · Z (S) $4410
1910.305 G01 IV
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $1,890 · Current $1,323 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): a) Printing Press Room Near Press 42 - On or about February 2, 2012, employees were exposed to burn hazards due to a damaged extension cord used as permanent wiring for the computer at Press 42. b) Printing Press Room Near Press 42 - On or about February 2, 2012, employees were exposed to burn hazards due to a damaged extension cord used as permanent wiring for the lighting located over the computer at Press 42. c) Shipping Area - On or about February 2012, employees were exposed to burn hazards due to the use of an extension cord used as permanent wiring for the digital scale.
Recent events (2)
- · I (S) $1323
- · Z (S) $1890
1910.305 B01 II
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $1,890 · Current $1,323 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Printing Press Room - On or about February 2, 2011, employees were exposed to burn hazards while working near a missing electrical knockout in an electrical box containing 110V.
Recent events (2)
- · I (S) $1323
- · Z (S) $1890
1904.29 B01
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation: a) Clear View Bag Company, Inc. - On or about February 12, 2012, the employer did not adequately describe injury or illness, parts of the body affected, and the object/substance that directly injured or made the employee ill as required in Column F of the OSHA Form 300 Log of Work-Related Injuries and Illnesses for three (3) recorded cases in 2007.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.179 B05
- Issued
- Feb 24, 2012
- Abate by
- Mar 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: On or about February 2, 2012, the following hoists were in use without load rating markings on each side of the hoist: (a) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 583741 (b) 54 Print Press - 1/4 ton Demag electric operated chain hoist Serial # 5331455
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Clear View BAG Company, INC.
View Clear View BAG Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326113)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331909382.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.