Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: CAPITAL AREA CONTRACTOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITAL AREA CONTRACTOR in 190 MENANDS ROAD, ALBANY, NY 12211 (NAICS 238160). OSHA activity number 331910331.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capital Area Contractor for free Get an email when a new federal OSHA severe-injury report for Capital Area Contractor is published. One employer, no account, unsubscribe in one click.
Site address
190 MENANDS ROAD
City
ALBANY
State
NY
ZIP
12211
Mailing
60 SIMMONS ROAD, HOOSICK FALLS, NY 12090
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 9, 2012
Abate by
Jul 14, 2012
Penalty
Initial $3,000 · Current $3,000
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a) At the jobsite, on or prior to February 2, 2012- Employees were working on a chicken ladder that was supported on a 5 on 12 sloped roof aproximately 21 feet from the ground; no fall protection system in use.
Recent events (1)
  • · Z (S) $3000

1926.454 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 9, 2012
Abate by
Jul 14, 2012
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.454(a)(2):  The employer did not ensure that employees received training in the correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used:      a)  At the jobsite, on or prior to February 2, 2012-  Employees were not trained on the appropriate use of fall protection in that they were not aware of when it was needed.
Recent events (1)
  • · Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331910331.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.