Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SHUR-WAY AUTO BODY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SHUR-WAY AUTO BODY in 3540 GREENWOOD, MAPLEWOOD, MO 63143 (NAICS 811121). OSHA activity number 331911784.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shur-Way Auto Body for free Get an email when a new federal OSHA severe-injury report for Shur-Way Auto Body is published. One employer, no account, unsubscribe in one click.
Establishment
SHUR-WAY AUTO BODY
Site address
3540 GREENWOOD
City
MAPLEWOOD
State
MO
ZIP
63143
Mailing
3540 GREENWOOD, MAPLEWOOD, MO 63143
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
18
Ownership type
A

9 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.37(b)(2) Each exit was not clearly visible and marked by a sign reading "Exit":      1)  Lower body shop, the emergency exit by the Car-O-Liner power lift did not have an "EXIT" sign.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.106 E06 II

Serious Gravity 1 2 instances 3 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii):  Class I liquids were  dispensed into containers without the nozzle and container electrically interconnected:    1)  Paint shop, the 5-gallon container of flammable lacquer thinner used for dispensing was not grounded.  2)  CleanUp and Paint Prep building, the 5-gallon container of flammable lacquer thinner used for dispensing was not grounded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2):  The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    1)  For employees who were expected to use a fire extinguisher to fight an incipient stage fire, fire extinguisher training was not conducted annually.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 3 instances 3 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    1)  Lower body shop, one air nozzle used by employee(s) measured 100 p.s.i.   2)  Lower body shop, another air nozzle used by employee(s) measured 80 p.s.i.  3)  CleanUp and Paint Prep building, one air nozzle used by employee(s) measured 90 p.s.i.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.253 B04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    1) Lower body shop, two oxygen and two acetylene cylinders were stored together.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.305 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    1) Paint shop, the electrical panel box servicing the spray booth had a missing circuit breaker resulting in exposed wiring.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.305 B02 I

Serious Gravity 1 3 instances 2 exposed
Issued
Feb 27, 2012
Abate by
Mar 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    1)  Lower body shop, the receptacle box with the switch to turn the furnace on and off was missing a cover, resulting in exposed wiring.  2)  Parts shed, the receptacle box with the light switch (110V) was missing a cover, resulting in exposed wiring.  3)  CleanUp & Paint Prep building, the duplex receptacle outlet box was missing a cover, resulting in exposed wiring.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 2 instances 2 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    1)  Lower body shop, an extension cord running in front of the emergency EXIT was used to service the permanently located CAR-O-LINER power lift for the frame machine.  Temporary wiring was used in lieu of fixed wiring.  2) Lower body shop, an extension cord was used to service the permanently located automatic release for the air filtration system.  Temporary wiring was used in lieu of fixed wiring.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 27, 2012
Abate by
Apr 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    Visual inspections were not conducted as evidenced by:    1)  Lower body shop, the SP-125 Plus Lincoln Electric MIG welder (110V, 125 amp) had a missing ground pin.   2)  Lower body shop, there was lack of strain relief on the extension cord and plug servicing the CAR-O-LINER power lift.  3)  Storage closet,  the SP-135T Lincoln Electric MIG welder had damaged outer insulation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331911784.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.