On , OSHA opened a planned health inspection of SEABROOK BROTHERS & SONS, INC. in 85 FINLEY ROAD, SEABROOK, NJ 08302 (NAICS 311411). OSHA activity number 331912501.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEABROOK BROTHERS & SONS, INC.
- Site address
- 85 FINLEY ROAD
- City
- SEABROOK
- State
- NJ
- ZIP
- 08302
- Mailing
- 85 FINLEY ROAD, SEABROOK, NJ 08302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311411
- Employees
- 430
- Ownership type
- Private (A)
Citations
30 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 7, 2012
- Abate by
- Nov 30, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. Employees were exposed to a fall hazard in excess of four feet. a) Repack Room, Suction Line - An employee was observed standing on elevated facility piping while painting. The employee was exposed to falls in excess of 16 feet. On or about 2/27/12. b) Repack Room, Suction Line - While standing on elevated facility piping, an employee attached his fall protection to a pipe support not rated for at least 5000 pounds. The employee was exposed to a fall hazard in excess of 16 feet. On or about 2/27/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.23 C01
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) Ammonia Room/Platform by Condensers - The guardrail at the platform edge did not have a midrail. Employees were exposed to a fall of approximately 8 feet. On or about 2/21/12. b) Peg Line/Truck Dumping Area - The edge of the hopper where vegetables are dumped from trucks was not protected by guardrails. Employees were exposed to a fall of approximately 13 feet. On or about 2/21/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.24 H
- Issued
- Aug 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) Loading Dock Near Float Freezer #7 - The stairs did not have a railing on the right side decending. On or about 3/7/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.36 B01
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.36(b)(1): At least two exit routes were not available in the workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. a) Ammonia Room - There was only one emergency exit located in the ammonia room. IIAR Bulletin No. 112 (6/98) 4.2.1b requires that there be two exits from an ammonia machinery room. On or about 2/8/12. ABATEMENT NOTE: The exit routes must be located as far away as practical from each other so that if one exit route is blocked by a release of anhydrous ammonia, employees can evacuate using the second exit route. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 N
- Issued
- Aug 7, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(n): The employer did not establish and implement an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38: a) Establishment - The employer's written emergency response plan did not identify a second employee assembly area on the side of the plant opposite the carton storage warehouse where evacuated employees would assemble if the wind direction was from the east (towards the carton storage warehouse). On or about 2/8/12. b) Establishment - There was no fixed emergency evacuation alarm that when activated would notify all employees of an evacuation in a timely manner. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.120 Q06 III
- Issued
- Aug 7, 2012
- Abate by
- Apr 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.120(q)(6)(iii): Employees who participated as hazardous materials technicians, or were expected to participate as hazardous materials technicians, had not received at least 24 hours of training equal to the first responder operations level, and in addition have competency in the areas outlined in 29 CFR 1910.120(q)(6)(iii)(A) through (q)(6)(iii)(I) and/or the employer did not so certify: a) Establishment - Employees who were required to assess the severity of, and control a release of anhydrous ammonia did not receive training that, at a minimum, met the training requirements of a hazardous materials technician. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.165 B02
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.165(b)(2): The employee alarm could not be perceived above ambient noise or light levels by all employees in the affected portions of the workplace: a) Boiler Room - There was no audible or visual alarm to warn of a release of anhydrous ammonia outside of the entrance to the ammonia room. On or about 2/8/12. Abatement note 1: ASHRAE 15 2010, 8.11.2.1 requires that the alarm shall annunciate visual and audible alarms inside the refrigerating machinery room and outside each entrance to the refrigerating machinery room. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 D03 I B
- Issued
- Aug 7, 2012
- Penalty
- Initial $2,805 · Current $1,543 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process: a) Establishment - P&ID 112A and P&ID 107B for Condensers D7 & D8 did not show 6-HSD-207 going through the wall. On or about 2/8/12. b) Establishment - P&ID 104D for Freezer F5 shows 1 ?-HPSCL-700-3 line from Freezer F4 leading into Freezer F5, but there is no line on P&ID 104B for Freezer F4. It should show 1 ? HPSCL-700-3 from Intermediate Accumulators A1 and A2 P&ID 103A. On or about 2/8/12. c) Establishment - P&ID 103F for Pump Recirculator A11 does not show ICS line coming off of the vessel. On or about 2/8/12. d) Establishment - P&ID 103F for Pump Recirculator A11 shows 2-HPSCL-762-3 from P&ID 104F for Freezer F4 and 3-LTRL-708-3 to P&ID104F for Freezer F4. The lines both should show Freezer F8 not F4 as P&ID 104F is Freezer F8. On or about 2/8/12. e) Establishment - P&ID 103F for Pump Recirculator A11 shows 2-HPSCL-762-3 from P&ID 104F for Freezer F4 which should show the line as ICLS. On or about 2/8/12. f) Establishment - P&ID 105A shows a ?-HG-811 line that goes to Freezer F5 on P&ID 104D, there is no HG line that goes to Freezer F5 on P&ID 104D. On or about 2/8/12. g) Establishment - P&ID 105A shows a 1 ?-HG-803 that comes from Condensers D1-D6, Condensers D5 and D6 were decommissioned, P&ID should show Condensers D1-D4. On or about 2/8/12. h) Establishment - P&ID 110B- 1 ?-HPSCL-709 from Flash Intercooler A8 should show ICLS instead of HPSCL. On or about 2/8/12. i) Establishment - P&ID 112A line that shows to 3-HPL-307 to Receivers R1 and R2 on P&ID 102A should show to 3-HPL-358 to EQ on P&ID 102A. On or about 2/8/12 j) Establishment - P&ID 103A line 2-HPL-314-2 to A3 P&ID 103B should show ICLS not HPL on P&IDs 103A and P&ID 103B. On or about 2/8/12. k) Establishment - P&ID 103C outgoing line from Accumulator A6 2-HPSCL-701 to A7 on P&ID 103D should show ICLS not HPSCL on P&ID 103C and P&ID103D. On or about 2/8/12. l) Establishment - P&ID 103E line from Freezer F5 1 ?-HPSCL-700-3 P&ID 104D should show ICLS not HPSCL. On or about 2/8/12. m) Establishment - P&ID 105A line 6-LSS-508-3-SP from Plate Freezers 1 and 3 to Freezer F8 should show Freezer F7. On or about 2/8/12. n) Establishment - The ball valves on each of the oil pots and oil legs were not shown on any of the P&IDs. On or about 2/8/12.
Recent events (2)
- · I (S) $1542.75
- · Z (S) $2805
1910.119 E03 I
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(i): The process hazard analysis did not address the hazards of the process: a) Ammonia Room - The hazard of operating a forklift in the aisle between compressors C8 and C11 was not identified in the Process Hazard Analysis conducted in February of 2010. There were no barriers in place to prevent ammonia refrigeration equipment including, but not limited to compressors C8 and C11 from being struck. On or about 2/8/12. b) Ammonia Room - The hazard of storing flammable and combustible liquids in the ammonia room was not addressed in the Process Hazard Analysis conducted in February of 2010. There was a flammable storage cabinet containing flammable liquids located along the east wall of the ammonia room. IIAR 112 4.2.1a does not permit storing flammables and combustibles in an ammonia machinery room. On or about 2/8/12. c) Ammonia Room - The hazard of storing flammable and combustible liquids in the ammonia room was not addressed in the Process Hazard Analysis conducted in February of 2010. Combustibles such as, but not limited to 55 gallon drums of lubricants were stored in the ammonia room. IIAR 112 4.2.1a does not permit storing flammables and combustibles in an ammonia machinery room. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 E03 V
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address facility siting: a) Ammonia Room - The door leading from the boiler room to the ammonia room was not self-closing per ANSI/ASHRAE Standard 15-2010 8.11.2. It was binding to the floor and had to be forcibly pulled closed. This was not addressed in the 2010 PHA. On or about 2/8/12. b) Ammonia Room, upper part of the east wall - The openings around an 8" water discharge pipe from the condensers to the freezers, and a branch water discharge pipe that passed through the wall to the adjacent production area through were not sealed per ANSI/ASHRAE Standard 15-2010 8.11.2. This was not addressed in the 2010 PHA. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 E03 VI
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(e)(3)(vi): The process hazard analysis did not address human factors: a) Ammonia Room - Hot gas valve, HV108, located above condenser D1 could not be readily accessed from the condenser platform in an emergency per IIAR 4.3 (e) without having to climb onto condenser D1. The valve was approximately 29" above the condenser and 34" from the side of the condenser. This was not addressed in the 2010 PHA. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 E05
- Issued
- Aug 7, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not assure that PHA recommendations were resolved in a timely manner: a) Ammonia Room - The labeling of ammonia piping, identified in the 2010 process hazard analysis was not corrected in a timely manner. Piping including, but not limited to equalizing line (3 EQ152), the trap from condensers to receivers (3 304 HPL), and 2 HPL 350 were not labeled per IIAR Bulletin 114, section 4.1. On or about 2/8/12. b) Ammonia Room - The labeling of ammonia piping, identified in the 2010 process hazard analysis was not corrected in a timely manner. The arrow indicating the direction of flow of the hot gas line from condensers D1 to D4 was incorrect. The direction of flow was in the opposite direction. On or about 2/8/12. c) Production Areas -The labeling of ammonia piping, identified in the 2010 process hazard analysis was not corrected in a timely manner. Piping including, but not limited to 10-LSS-508-3-SP, A10 recirculating line (4-691-LTRL), 1.5-HPSCL-700, and 12-LSS-556 were not labeled per IIAR Bulletin 114, section 4.1. On or about 2/8/12. d) Ammonia Room - Manual and automatic emergency isolation valves were not included in a regular maintenance program. This item, identified in the 2010 process hazard analysis, was not corrected in a timely manner. On or about 2/8/12. Abatement Note: Labeling shall meet the requirements of IIAR Bulletin 114, Guidelines for: Identification of Ammonia Refrigeration Piping and System Components including the identity of the contents, physical state, pressure level, and direction of flow. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 F01 I E
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(i)(E): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information that addressed the steps for each operating phase, including emergency operations: a) Northwest corner of property - The employer did not develop and implement written standard operating procedures for deactivation of the solar panels in the event of a power failure, on or about 2/8/12. b) Throughout facility - The employer did not update their written standard operating procedures to reflect the actions to be taken to start the generators in the event of a power failure, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 F01 III B
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(B): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information that addressed health and safety considerations, such as precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment: a) Throughout facility - The employer did not develop and implement a written standard operating procedure to address the actions to be taken to remove trapped liquid from a pipe line, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.119 H02 I
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(h)(2)(i): The employer, when selecting a contractor, did not obtain and evaluate information regarding the contract employer's safety performance and programs: a) Establishment - The employer did not obtain and evaluate information regarding the contract employers safety performance and programs. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 J02
- Issued
- Aug 7, 2012
- Abate by
- Apr 1, 2013
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment: a) Establishment -The employer did not establish written procedures for the inspections of production equipment including, but not limited to pumps, valves, pipes, vessesls. On or about 2/8/12. b) Establishment - The employer did not establish written procedures for job tasks including, but not limited to the removing, replacing, adjusting, cleaning, or opening of process equipment. On or about 2/8/12. c) Establishment - The employer did not establish written procedures for defrosting process equipment including, but not limited to PRVs, compressors, valves, cleaning condenser tubes, pump defrost for required inspections per IIAR B110. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 J04 II
- Issued
- Aug 7, 2012
- Abate by
- Apr 1, 2013
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures did not follow recognized and generally accepted good engineering practices (note: this standard applies to pressure vessels and storage tanks; piping systems (including piping components and valves); relief and vent systems and devices; emergency shutdown systems; controls (including monitoring devices and sensors, alarms, and interlocks) and; pumps as referenced by sections (j)(1)-(j)(1)(vi) of this standard): a) Ammonia Room - The compressor motors and drive guards were not inspected for wear on the bearing surfaces as per IIAR B110 section 6.3.2. On or about 2/8/12. b) Ammonia Room - The compressor and motor drive alignment were not inspected annually as per IIAR B110 section 6.3.2. On or about 2/8/12. c) Ammonia Room - The condition and tightness of the foundation bolts was not checked annually as per IIAR B110 section 6.3.2. On or about 2/8/12. d) Ammonia Room and Production Areas - The scope of the 5 year independent full inspection did not cover all vessels and heat exchangers, of which conditions not in compliance with the standards and RAGAGEP were noted as per IIAR B110 section 6.4.4.1 (Independent Full Inspection). On or about 2/8/12. e) Ammonia Room - A detailed examination of the external surface or of the insulation applied to the external surface of vessels and heat exchangers was not made at intervals of no more than 12 months. Pump Recirculators A8 and A9 had not been inspected as per IIAR B110 section 6.4.3- Annual Inspection. On or about 2/8/12. f) Ammonia Room - Inspections of underlying vessels or heat exchangers such as but not limited to Pump Recirculators A8 and A9 were not carried out when insulation was unsound or damaged as per IIAR B110 section 6.4.4.3. On or about 2/8/12. g) Ammonia Room and Productions Areas - Access to pumps and adjacent lines was not ensured preventing access and visual inspection for pumps and associated piping including but not limited to HV 926 and HV 923 as per IIAR B110 section 6.5.2. On or about 2/8/12. h) Ammonia Room - All insulated piping and associated components such as flanges and supports were not inspected annually for damage to or deterioration of the piping or its protective finish as per IIAR B110 section 6.7.1. Pitting and rusting was noted on Equalizing line 3-EQ-152 (P&ID 102A). On or about 2/8/12. i) Ammonia Room - All insulated piping and associated components such as flanges and supports were not inspected annually for damage to or deterioration of the piping or its protective finish as per IIAR B110 section 6.7.1. Pitting and rusting was noted on the the Trap from Condensers to Receivers 3-304-HPL (P&ID 102A). On or about 2/8/12. j) Ammonia Room - All insulated piping and associated components such as flanges and supports were not inspected annually for damage to or deterioration of the piping or its protective finish as per IIAR B110 section 6.7.1. Pitting and rusting was noted on 2-HPL-302 to Intermediate Accumulator A1 from Receivers (P&ID 102A & 103A). On or about 2/8/12. k) Ammonia Room - All insulated piping and associated components such as flanges and supports were not inspected annually for damage to or deterioration of the piping or its protective finish as per IIAR B110 section 6.7.1. Pitting and rusting was noted on 6-HPL-309 painted over pipe (P&ID 107A). On or about 2/8/12. l) Ammonia Room - All insulated piping and associated components such as flanges and supports were not inspected annually for damage to or deterioration of the piping or its protective finish as per IIAR B110 section 6.7.1. Pitting and rusting was noted on 2-HPL-350 to Flash Intercooler A8 (P&ID 102A & 110B). On or about 2/8/12. m) Ammonia Room - All insulated piping and associated components such as flanges and supports were not inspected annually for damage to or deterioration of the piping or its protective finish as per IIAR B110 section 6.7.1. Pitting and rusting was noted on Pipe and hand valve off of Receiver R1 into site glass 2HV 104 (no pipe number) (P&ID 102A). On or about 2/8/12. n) Ammonia Room and Production Areas - The external condition of the insulation and supports were not inspected annually as per IIAR B110 section 6.7.2. On or about 2/8/12. o) Ammonia Room - Sections of insulation which were in poor condition were not removed and the integrity of the exposed piping was not determined with the aid of non-destructive testing techniques as per IIAR B110 section 6.7.2. Ice breaking through insulation was noted including but not limited to pipes associated with valves 10HV 915, 10 LAH 916, 10 M 936, 10 HV 918, 10 HV 917, line going into top of Pump Recirculator A9 1-LTRL-674-3, LTRL-675-3, LTRL-676-3 and Pump Recirculator A10 3-LTRL-691-3 in the area near 3 HV 1022, 1065, 1063. On or about 2/8/12. p) Ammonia Room - Protective coatings, insulation and vapor seal was not re-applied as per IIAR B110 section 6.7.2. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 L01
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(l)(1): The employer did not establish written procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affected a covered process. a) Northwest corner of property -The employer did not establish and implement written management of change procedures for the installation of solar panels, on or about 2/8/12. b) Ammonia compressor room near main entrance - The employer did not establish and implement written management of change procedures for the installation of a modified Hansen auto purger, on or about 2/8/12. c) Penthouse on roof - The employer did not establish and implement written management of change procedures for the removal of aluminum lines in evaporators E9-12 to the installation of stainless steel braided lines, on or about 2/8/12. d) Above receivers in ammonia compressor room: The employer did not establish and implement written management of change procedures for the removal of aluminum lines in condensers D1-3 to the installation of stainless steel lines, on or about 2/8/12. e) Throughout facility - The employer did not establish and implement written management of change procedures for new standard operating procedures involving the operation of the emergency generators due to the installation of the solar panels, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.119 O01
- Issued
- Aug 7, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.119(o)(1): The employer did not verify that the procedures and practices developed under the standard were being followed: a) Establishment - A compliance audit of the ammonia refrigeration system containing approximately 40,000 pounds of anhydrous ammonia was not conducted. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.133 A01
- Issued
- Aug 7, 2012
- Abate by
- Aug 16, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Chemical Mixing Area by Brine Tank - While mixing Chlor-Foam Plus, a corrosive sanitation chemical, employees did not wear a face shield. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.151 C
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Boiler room outside of main entrance to ammonia compressor room - The employer did not comply with IIAR B109 Minimum Safety Criteria for a Safe Ammonia Refrigeration System section 4.10.10, which requires installation of a deluge safety shower, capable of providing 15 minutes of continuous flushing, outside of the ammonia compressor room door, on or about 2/8/12. b) Boiler room outside of main entrance to ammonia compressor room - The employer did not comply with IIAR B109 Minimum Safety Criteria for a Safe Ammonia Refrigeration System section 4.10.10, which requires installation of an emergency eyewash station, capable of providing 15 minutes of continuous flushing, outside of the ammonia compressor room door, on or about 2/8/12. c) Boiler room outside of main entrance to ammonia compressor room - The employer did not install an emergency eyewash station, capable of providing 15 minutes of continuous flushing, in the boiler room where employees worked with PurCide 25, a corrosive chemical, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C01
- Issued
- Aug 7, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $2,805 · Current $1,543 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not ensure that a written respiratory protection program with worksite-specific procedures was established and implemented to include the provisions of (i)-(ix), as applicable: a) Throughout facility - The written respiratory protection program did not contain specific details including, but not limited to, procedures for respiratory selection, emergency use of the SCBA, procedures for repairing when required, procedures for inspections, procedures to ensure adequate air quality, quantity and flow of breathing air for SCBAs, training topics to address the hazards which they be exposed to under routine and emergency situations and the frequency of fit testing, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1542.75
- · Z (S) $2805
1910.134 F02
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: a) Throughout facility - The employer did not ensure that employees required to use MSA full face air purifying respirators with ammonia HEPA combination cartridges (GME P100) and Scott Pressure-PAK 2.2 SCBAs received annual fit tests, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 K
- Issued
- Aug 7, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable, and effective annual training to employees who were required to use respirators: a) Throughout facility -The employer did not provide effective annual training for employees required to use MSA full face air purifying respirators with ammonia HEPA combination cartridges (GME P100) and Scott Pressure-PAK 2.2 SCBAs, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C04 I
- Issued
- Aug 7, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $4,675 · Current $2,571 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Ammonia Room - The employer did not have specific written procedures for locking out compressors prior to performing maintenance on them. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $2571.25
- · Z (S) $4675
1910.147 D04 I
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Ammonia Room - Valves controlling ammonia flow in and out of Compressor #3 had not been locked out prior to removing the compressor for maintenance. On or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 G02
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $2,805 · Current $1,543 Reduced
General-duty citation text
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks: a) Warehouse Fork Truck Charging Area - Charger cables were not protected from damage caused by being run over by fork trucks. Cables on the floor had visible damage to the outer rubber cover. On or about 3/7/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1542.75
- · Z (S) $2805
1910.178 L04 II B
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics was not provided to the operator when the operator had been involved in an accident or near-miss incident: a) Establishment - Following incidents where employees were injured by fork trucks, the operators had not received the required retraining. On or about 3/7/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 L04 III
- Issued
- Aug 7, 2012
- Abate by
- Nov 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years: a) Establishment - Operators of fork trucks did not have their performance evaluated at least once every three years. On or about 3/7/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 H03 IV A
- Issued
- Aug 7, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(iv)(A): Respirators maintained for emergency use were not certified with the date the inspection was performed, the name (or signature) of the person who made the inspection, the findings, required remedial action, and a serial number or other means of identifying the inspected respirator: a) Throughout facility - The employer did not certify the inspections of Scott Pressure-PAK 2.2 SCBAs, used for emergency purposes, by documenting the date of the inspections, the name of the inspector, the findings, any required remedial action and an identification number for the SCBA, on or about 2/8/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Seabrook Brothers & Sons, INC.
View Seabrook Brothers & Sons, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311411)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331912501.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.