TRAVIS AFB, CA ·
OSHA Inspection: U.S. AIR FORCE CIVIL ENGINEER SUPPORT AGENCY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. AIR FORCE CIVIL ENGINEER SUPPORT AGENCY in 730 E STREET BLDG. 1205, TRAVIS AFB, CA 94535 (NAICS 928110). OSHA activity number 331913277.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. AIR FORCE CIVIL ENGINEER SUPPORT AGENCY
- Site address
- 730 E STREET BLDG. 1205
- City
- TRAVIS AFB
- State
- CA
- ZIP
- 94535
- Mailing
- OL-A AFCESA/CERMIRT 730 E STREET BLDG. 1205, TRAVIS AFB, CA 94535
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 25
- Ownership type
- Federal government (D)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 27, 2012
- Abate by
- May 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a). Engine Rebuild Area - Noted on or about 2/13/12, the rotating chuck of a horizontal lathe was not provided with safe guarding to prevent unintentional contact.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Apr 27, 2012
- Abate by
- Apr 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. Component Repair Shop Noted on or about 2/13/12 a Baldor 8 bench grinder, serial # G-8-341-11 was missing the tongue guard. b. Engine Rebuild Area - Noted on or about 2/13/12 a Baldor 8 bench grinder, serial #1216W had a 1/2" measured space between the tongue guard and the grinding wheel. The guard should be adjusted to no greater than 1/4".
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331913277.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.