SAINT LOUIS, MO —
OSHA Inspection: GUNTHER ELECTRONICS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUNTHER ELECTRONICS in 5080 DELMAR BLVD., SAINT LOUIS, MO 63108 (NAICS 423930). OSHA activity number 331913434.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GUNTHER ELECTRONICS
- Site address
- 5080 DELMAR BLVD.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63108
- Mailing
- 5080 DELMAR BLVD., SAINT LOUIS, MO 63108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L01 II
- Issued
- Feb 15, 2012
- Abate by
- Mar 8, 2012
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a Establishment: Operators of forklifts were not provided required training prior to operating a forlklift. Abatement certification and abatement documentation are required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.305 B02 I
- Issued
- Feb 15, 2012
- Abate by
- Mar 1, 2012
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Computer testing area: A duplex recpetacle outlet was not covered. b) Scrap area: A fluorescent lighting fixture was powered from a switch which was not covered. Abatement certification and abatement documentation are required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331913434.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.