TWIN FALLS, ID ·
OSHA Inspection: COMMUNITY COUNCIL OF IDAHO, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMMUNITY COUNCIL OF IDAHO, INC. in 1122 WASHINGTON STREET, S., TWIN FALLS, ID 83302 (NAICS 236118). OSHA activity number 331913509.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMMUNITY COUNCIL OF IDAHO, INC.
- Site address
- 1122 WASHINGTON STREET, S.
- City
- TWIN FALLS
- State
- ID
- ZIP
- 83302
- Mailing
- 317 HAPPY DAY BLVD., CALDWELL, ID 83607
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 7
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.404 B01 I
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $4,250 · Current $2,125 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) Milagro Housing Units 11, 28, and 33: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees were operating electric power tools without a GFCI or assured equipment grounding conductor program. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $2125
- · Z (S) $4250
1926.405 B02
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) Milagro Housing Units 11, 28, and 33: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees were exposed to energized outlets and switches that did not have covers. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.416 A01
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) El Milagro Housing units 11, 28, and 33: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees were remodeling the inside of homes that had energized exposed live parts from outlets and switches. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.417 B
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.417(b): Equipment or circuits that were de-energized did not have tags attached at all points where such equipment or circuits could be energized: a) Milagro Housing Units 11, 28, and 33: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees were exposed to electric circuits that had not been locked out or tagged out. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.405 D
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front: a) Milagro Housing Unit # 28: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees and supervisors were exposed to unguarded live conductors from the main electric service panel that was not dead front. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $4250
1926.405 E01
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: a) Milagro housing unit # 28: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees and supervisors were exposed to the outdoor main electric service panelboard that had only a piece of plywood screwed to the cabinet, instead of the required factory supplied metal cover. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C02 I
- Issued
- Apr 30, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference 1926.103): a) El Milagro housing units # 11, 28, and 33: On February 6, 2012, and times prior thereto, YouthBuild apprentice employees were using MSA model # 10102229 N-95 filtering face pieces an a voluntary basis without the information contained in Appendix D to 29 CFR 1910.134. Note: Abatement certification is required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 236118)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331913509.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.