OSHA Inspection: MARLITE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARLITE, INC. in 202 HARGER ST., DOVER, OH 44622 (NAICS 321911). OSHA activity number 331914788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marlite, INC. — free Get an email when a new federal OSHA severe-injury report for Marlite, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MARLITE, INC.
Site address
202 HARGER ST.
City
DOVER
State
OH
ZIP
44622
Mailing
202 HARGER ST., DOVER, OH 44622
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
195
Ownership type
A

15 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.23(c)(1(i)):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.      a. At the workplace in the area above the Backroom, on 02/22/2012, the railing did not have an intermediate rail or toeboard.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.24 C

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.24(c):     "Stair strength." Fixed stairways shall be designed and constructed to carry a load of five times the normal live load anticipated but never of less strength than to carry safely a moving concentrated load of 1,000 pounds.    a. At the workplace in the Insert Area, on or about 02/22/2012, employees traversed a stairway that did not meet the required stair strength in that one of the risers had broken under load.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.24 H

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 6, 2012
Abate by
Aug 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.24(h):     "Railings and handrails." Standard railings shall be provided on the open sides of all exposed stairways and stair platforms. Handrails shall be provided on at least one side of closed stairways preferably on the right side descending. Stair railings and handrails shall be installed in accordance with the provisions of 1910.23.      a. At the workplace in the Insert Area, on or about 02/22/2012, employees traversed a stairway to access the roof without the protection of a  standard railing. This railing was missing a midrail and did not extend the entire length of the stairs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.37(a)(4):     Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times.    a. At the workplace in the Sample Room, on 02/22/2012, the exit sign's emergency lighting was not in working order.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.37 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4):     If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times.      a. At the workplace in the Compressor Room, on 02/22/2012,  no exit sign was present where the direction of travel or discharge to the exit was not immediately apparent.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 1 2 instances 2 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.212(b):     Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:      a. At the workplace, in the A1 Area, a Delta Drill Press, Serial #010167,  was not securely anchored to prevent walking or moving.    b. In the workplace, in the Assembley Area, a Delta-Rockwell Drill Press, Serial #1582882, was not securely anchored to prevent walking or moving.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    a.  At the workplace in the Super Hog Area, on or about 02/22/2012, employees used compressed air for cleaning purposes that was not reduced to less than 30 p.s.i. The air used for parts cleaning measured 36 psi at the time of inspection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3000

1910.303 G01 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.303(g)(1)(i)(A):     The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;    a. At the workplace in the Plank Splitter Area, on or about 02/22/2012,  an employee's working space was directly in front of the electrical disconnects for Choppers 1, 2, and 3.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.304 G05

Other-than-serious 1 instance 4 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.304(g)(5):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.    a. At the workplace in the Sample room, on 02/22/2012, a Patton brand electrical fan did not have a continuous path to ground due to a missing grounding pin.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4000

1910.305 G01 IV A

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.305(g)(1)(iv)(A):     Unless specifically permitted otherwise, flexixible cords and cables may not be used as a substitute for the fixed wiring of a structure;        a. In the A1 Area at the workplace, on 02/14/12, a flexible cord was used as a substitute for the fixed wiring of a Milwaukee Mitre Saw.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.212 A01

Repeat Gravity 5 4 instances 4 exposed
Issued
Jul 6, 2012
Abate by
Aug 3, 2012
Penalty
Initial $25,000 · Current $3,000 Reduced
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a. At the workplace, in the A1 Area, a Delta Drill Press, Serial #010167,  had a rotating chuck and cutting bit that was inadequately guarded.    b. In the workplace, in the Assembley Area, a Delta-Rockwell Drill Press, Serial #1582882, had a rotating chuck and cutting bit that was inadequately guarded.    c. In the workplace, in the A1 Area, a Reuland Drill Press had a rotating chuck that was inadequately guarded.    d. In the workplace, near the Timecard Station, a Canedy-Otto Drill Press, Serial #J2299, had a cutting bit that was inadequately guarded        The employer, Marlite, Inc. was previously cited for a violation of this occupational safety and health standard or it's equivalent (1910.212(A)(1)), which was contained in OSHA inspection 311833719, citation number 1, item number 1, and was affirmed as final order on May 28th, 2008 with respect to a aorkplace located at 202 Harger St., Dover, Ohio 44622.
Recent events (2)
  • — I (R) $3000
  • — Z (R) $25000

1904.29 B01

Deleted Other-than-serious 1 instance 195 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.29(b)(1):     The employer did not provide the required injury or illness descriptions on the Log of Work-Related Injuries and Illnesses, OSHA Form 300:    a. On or about 02/22/12 at the workplace, the employer did not provide the required injury or illness descriptions under column F on the Log of Work-Related Injuries and Illnesses for 2011.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1000

1904.29 B01

Deleted Other-than-serious 1 instance 195 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.29(b)(1):     The employer did not provide the required injury or illness descriptions on the Log of Work-Related Injuries and Illnesses, OSHA Form 300:    a. On or about 02/22/12 at the workplace, the employer did not provide the required injury or illness descriptions under column F on the Log of Work-Related Injuries and Illnesses for 2010.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1000

1904.29 B01

Deleted Other-than-serious 1 instance 195 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.29(b)(1):     The employer did not provide the required injury or illness descriptions on the Log of Work-Related Injuries and Illnesses, OSHA Form 300:    a. On or about 02/22/12 at the workplace, the employer did not provide the required injury or illness descriptions under column F on the Log of Work-Related Injuries and Illnesses for 2009.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1000

1904.29 B01

Deleted Other-than-serious 1 instance 195 exposed
Issued
Jul 6, 2012
Abate by
Jul 13, 2012
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.29(b)(1):     The employer did not provide the required injury or illness descriptions on the Log of Work-Related Injuries and Illnesses, OSHA Form 300:    a. On or about 02/22/12 at the workplace, the employer did not provide the required injury or illness descriptions under column F on the Log of Work-Related Injuries and Illnesses for 2008.