Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WAYNE'S ELECTRICAL SERVICE CORPORATION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WAYNE'S ELECTRICAL SERVICE CORPORATION in 308-314 EAST 53RD STREET, CHICAGO, IL 60647 (NAICS 238210). OSHA activity number 331915363.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wayne'S Electrical Service Corporation for free Get an email when a new federal OSHA severe-injury report for Wayne'S Electrical Service Corporation is published. One employer, no account, unsubscribe in one click.
Site address
308-314 EAST 53RD STREET
City
CHICAGO
State
IL
ZIP
60647
Mailing
4323 W. CERMAK ROAD, CHICAGO, IL 60623
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.405 A02 II E

Serious Gravity 5 2 instances 5 exposed
Issued
May 4, 2012
Abate by
May 9, 2012
Penalty
Initial $3,000 · Current $3,000
29 CFR 1926.405(a)(2)(ii)(E):  All lamps for general illumination shall be protected from accidental contact or breakage: Metal-case sockets shall be grounded:    a)  On or about February 16, 2012, at the jobsite located 308-312 E. 53rd Street, Chicago, IL. - Employees performing electrical operations in a rehab were exposed to electrical hazards due to the temporary lights having missing cages.
Recent events (1)
  • · Z (S) $3000

1926.405 A02 II F

Serious Gravity 5 2 instances 5 exposed
Issued
May 4, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension:    a)  On or about February 16, 2012, at the jobsite located 308-312 E. 53rd Street, Chicago, IL. - Employees performing electrical operations in a rehab were exposed to electrical hazards, due to temporary lights being suspended by their cords.
Recent events (1)
  • · Z (S) $0

1926.405 G02 III

Serious Gravity 5 2 instances 5 exposed
Issued
May 4, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iii): Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced:    a)  On or about February 16, 2012, at the jobsite located 308-312 E. 53rd Street, Chicago, IL. - Employees were performing electrical operations in a rehab using temporary electrical lines that were spliced to service the temporary lights and receptacle outlets, thereby exposing employees to electrical hazards.
Recent events (1)
  • · Z (S) $0

1926.501 B01

Serious Gravity 10 5 instances 5 exposed
Issued
May 4, 2012
Abate by
May 9, 2012
Penalty
Initial $4,200 · Current $4,200
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface (horizontal and verticalsurface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a)  On or about February 16, 2012, at the jobsite located 308-312 E. 53rd Street, Chicago, IL. - Employees working in a rehab performing electrical work were exposed to fall hazards due to unprotected sides of the porch landings, thereby exposing employees to fall hazards of approximately twenty three (23) feet.
Recent events (1)
  • · Z (S) $4200

1926.501 B14

Serious Gravity 5 5 instances 5 exposed
Issued
May 4, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:    a)  On or about February 16, 2012, at the jobsite located 308-312 E. 53rd Street, Chicago, IL. - Employees working in a rehab performing electrical work were exposed to fall hazards due to unprotected window and wall openings, thereby exposing employees to fall hazards of approximately twenty five (25) feet.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331915363.