Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WISCONSIN METAL FAB, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WISCONSIN METAL FAB, INC. in 1875 OLSON DR., CHIPPEWA FALLS, WI 54729 (NAICS 332322). OSHA activity number 331916031.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wisconsin Metal FAB, INC. — free Get an email when a new federal OSHA severe-injury report for Wisconsin Metal FAB, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1875 OLSON DR.
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
1875 OLSON DR., CHIPPEWA FALLS, WI 54729
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
75
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 21, 2012
Abate by
Aug 3, 2012
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate:  (a) Production area, laser table and material handling tower; Laser table operators who performed maintenance activities on locked out equipment were not trained as authorized employees.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.147 D04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Jun 21, 2012
Abate by
Aug 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Production area; Each authorized employee did not affix a lock while performing maintenance activities on the laser table and material feed tower.  (b) Production area; Press brakes were not locked out during maintenace activities, such as setup operations on Accurpress (250, 100, and 60 ton) hydraulic press brakes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 21, 2012
Abate by
Jul 13, 2012
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Machining area; Guarding was not provided for a chuck on a Jet brand manual lathe.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.252 B02 III

Serious Gravity 1 2 instances 10 exposed
Issued
Jun 21, 2012
Abate by
Jun 28, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  (a) Production area; Cardboard was used in place of noncombustible screens and noncombustible screens or shields were not positioned to protect employees working adjacent to manual welding station from arc welding rays.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.101 B

Other-than-serious 1 instance 3 exposed
Issued
Jun 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  (a) South end of machining area; A compressed gas cylinder of Nitrogen was not secured.