Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: COON'S TREE SERVICE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COON'S TREE SERVICE in 2920 1/2 E. MULBERRY ST., FORT COLLINS, CO 80524 (NAICS 561730). OSHA activity number 331916916.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coon'S Tree Service for free Get an email when a new federal OSHA severe-injury report for Coon'S Tree Service is published. One employer, no account, unsubscribe in one click.
Establishment
COON'S TREE SERVICE
Site address
2920 1/2 E. MULBERRY ST.
City
FORT COLLINS
State
CO
ZIP
80524
Mailing
2920 1/2 E. MULBERRY ST., FORT COLLINS, CO 80524
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
3
Ownership type
Private (A)

1 citation on file for this inspection.

1910.67 C02 V

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 23, 2012
Abate by
Apr 13, 2012
Penalty
Initial $1,800 · Current $1,800
29 CFR 1910.67(c)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift:     (a)Coon's Tree Service @ 2920 1/2 E. Mulberry St., Fort Collins, CO 80524: On and before February 12th, 2012, the employer did not ensure that an employee who was aloft in a raised aerial lift was wearing a body belt with a lanyard attached to the basket. This condition exposed the employee to fall hazards of up to 15 feet.    Abatement Note: Among other methods, American National Standards Institute (ANSI) Z133.1 - 2000, Section 6.2.2 provides: "Aerial devices shall be provided with a point of attachment to secure a full body harness with a shock-absorbing lanyard or body belt and lanyard. Fall protection shall be worn when working aloft."
Recent events (1)
  • · Z (S) $1800

View Coon'S Tree Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331916916.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.