NEW YORK, NY —
OSHA Inspection: DCM ERECTORS INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of DCM ERECTORS INC. in WTC 4, 150 GREENWICH STREET, NEW YORK, NY 10006 (NAICS 238120). OSHA activity number 331918011.
Where did this inspection happen?
- Establishment
- DCM ERECTORS INC.
- Site address
- WTC 4, 150 GREENWICH STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10006
- Mailing
- 110 EAST 42ND STREET, NEW YORK, NY 10017
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 1000
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.1412 D01 II
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
29 CFR 1926.1412(d)(1)(ii): Control and drive mechanisms for apparent excessive wear of components and contamination by lubricants, water or other foreign matter. LOCATION: 150 Greenwich Street, New York, NY On or about 2/16/2012 Employer did not conduct shift inspections of control and drive mechanisms for contamination by water or other foreign matter. Water was found in the hydraulic fluid for the motors. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
- — F (O) $5000
- — C (S) $5000
- — Z (S) $5000
1926.1412 D01 VII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1412(d)(1)(vii): Wire rope,shift inspections were not inspected in accordance with 1926.1413(a). LOCATION: 150 Greenwich Street, New York, NY On or about 2/16/2012 Employer did not conduct shift inspections of the running wire rope section. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1417 O01
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $7000.00
General-duty citation text
29 CFR 1926.1417(o)(1) : The equipment was operated in excess of its rated capacity. LOCATION: 150 Greenwich St, New York , NY On or about 2/16/12 Employer lifted loads in excess of the cranes rated capacity. There were several loads hoisted by the crane which were in excess of 100% of the rated capacity during the crane's operation. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENATLY OF $1000 AS PER 29 CFR 1903.19
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1926.1417 O03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1417(o)(3)(ii): The operator must begin hoisting the load to determine, using a load weighing device, load moment indicator, rated capacity indicator, or rated capacity limiter, if it exceeds 75 percent of the maximum rated capacity at the longest radius that will be used during the lift operation. If it does, the operator must not proceed with the lift until he/she verifies the weight of the load in accordance with paragraph (o)(3)(i) of this section. LOCATION: 150 Greenwich St, New York , NY On or about 2/16/12 Employer lifted loads in excess of 75% of the cranes rated capacity and the operator did not verify the wieght of the load. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENATLY OF $1000 AS PER 29 CFR 1903.19
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1417 S
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1417(s): The operator must test the brakes each time a load that is 90% or more of the maximum line pull is handled by lifting the load a few inches and applying the brakes. In duty cycle and repetitive lifts where each lift is 90% or more of the maximum line pull, this requirement applies to the first lift but not to successive lifts. LOCATION: 150 Greenwich St, New York , NY On or about 2/16/12 The lifts of the loads in excess of 90% were completed and the brakes were not tested. From review of the operation of the loads being lifted there was no stoppage to test the brakes as the load was being lifted. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENATLY OF $1000 AS PER 29 CFR 1903.19
Recent events (3)
- — F (S) $0
- — C (S) $5000
- — Z (S) $5000
1926.1425 E02
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
29 CFR 1926.1425(e)(2): Employees not essential to the operation were permitted in the fall zone (directly under the load). LOCATION: 150 Greenwich St, New York, NY On or about 2/16/12 Employer allowed non-essential employees to work in areas under crane load. SOther employers and employees not associated with the operation of hoisting the load were permitted to walk, use llifts and work in the fall zone. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
- — F (O) $5000
- — C (S) $5000
- — Z (S) $5000
More inspections at DCM ERECTORS INC.
NEW YORK, NY—2012-06-27 00:00:00
DCM ERECTORS, INC.
NEW YORK, NY—2012-04-17 00:00:00
DCM ERECTORS INC.
NEW YORK, NY—2012-01-05 00:00:00
DCM ERECTORS INC.
NEW YORK, NY—2011-09-27 00:00:00
DCM ERECTORS INC.
NEW YORK, NY—2011-04-18 00:00:00
DCM ERECTORS INC.
View DCM ERECTORS INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
LYNN, MA—2026-07-16 00:00:00
A.M.B. IRON LLC
EL PASO, TX—2026-07-15 00:00:00
SURE STEEL
NAMPA, ID—2026-07-15 00:00:00
ELITE STEEL ERECTORS, LLC
DALTON, MA—2026-07-13 00:00:00
BERKSHIRE BRIDGE & IRON COMPANY, INC.
GARDENDALE, AL—2026-07-09 00:00:00
ANDINO'S IRON WORKERS, LLC
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source