DUTCH HARBOR, AK —
OSHA Inspection: PREMIER PACIFIC SEAFOODS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIER PACIFIC SEAFOODS, INC. in M/V EXCELLENCE NORTH PACIFIC FUEL DOCK, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 331919910.
Where did this inspection happen?
- Establishment
- PREMIER PACIFIC SEAFOODS, INC.
- Site address
- M/V EXCELLENCE NORTH PACIFIC FUEL DOCK
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- 111 WEST HARRISON STREET, SEATTLE, WA 98119
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311712
- Employees
- 144
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees Cargo hatch starboard side second deck: On or about February 12, 2012 and times prior thereto, the CM 622 1 ton chain hoist used to lift the hatch had a sprung hook, no latch and was not rated for the capacity of the hatch. This condition exposed employees to struck-by hazards. Cargo hatch port side second deck: On or about February 12, 2012 and times prior thereto, the CM 622 chain hoist used to lift the hatch had no latch on the hook. This condition exposed employees to struck-by hazards.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1915.56 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.56(b)(4): Cables in poor repair shall not be used. When a cable other than the cable lead referred to inparagraph (b)(2) of this section becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means of rubber and friction tapes or other equivalent insulation. Processing deck: On or about February 12, 2012 and times prior thereto, welding cable available for use had two cuts to the conductor. This exposed employees to possible shock hazards from coming in contact with the conductor while welding with the cable.
Recent events (1)
- — Z (O) $0
More inspections at PREMIER PACIFIC SEAFOODS, INC.
SEATTLE, WA—2012-09-13 00:00:00
PREMIER PACIFIC SEAFOODS, INC
DUTCH HARBOR, AK—2012-07-12 00:00:00
PREMIER PACIFIC SEAFOODS, INC.
DUTCH HARBOR, AK—2012-02-12 00:00:00
PREMIER PACIFIC SEAFOODS, INC.
DUTCH HARBOR, AK—2012-02-12 00:00:00
PREMIER PACIFIC SEAFOODS, INC.
View PREMIER PACIFIC SEAFOODS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311712)
ANACORTES, WA—2026-07-01 00:00:00
WA317991905 - TRIDENT SEAFOODS CORPORATION
BAY CITY, OR—2026-06-11 00:00:00
317744508 - PACIFIC OYSTER CO
EVERETT, WA—2026-04-13 00:00:00
WA317990716 - DEEP SEA FISHERIES INC
ANACORTES, WA—2025-10-07 00:00:00
WA317988174 - SUGIYO USA INC
BELLINGHAM, WA—2025-08-12 00:00:00
WA317987368 - Q SEA SPECIALTY SERVICES LLC
More inspections in AK
ANCHORAGE, AK—2026-07-10 00:00:00
AK, INC
ANCHORAGE, AK—2026-07-08 00:00:00
ONE STOP SERVICES
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08 00:00:00
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07 00:00:00
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331919910.