Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: LA BELLA HOME IMPROVEMENTS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LA BELLA HOME IMPROVEMENTS in 120 WOODMERE BLVD, WOODMERE, NY 11598 (NAICS 236115). OSHA activity number 331921239.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LA Bella Home Improvements — free Get an email when a new federal OSHA severe-injury report for LA Bella Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
120 WOODMERE BLVD
City
WOODMERE
State
NY
ZIP
11598
Mailing
4 KIME AVENUE, NORTH BABYLON, NY 11703
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 A06

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 23, 2012
Abate by
Mar 26, 2012
Penalty
Initial $3,000 · Current $1,750 Reduced
29 CFR 1926.451(a)(6):  Scaffolds were not designed by a qualified person:      a)  Worksite, Front of home - An employee was installing plywood sheathing while walking and working on a single 2x8in plank approximately 11ft above the ground below; on or about 2/24/12.      b)  Worksite, Rear of home - An employee was installing plywood sheathing while walking and working on a single 2x8in plank approximately 9ft above the ground below; on or about 2/24/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3000

1926.451 B02

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 23, 2012
Abate by
Mar 26, 2012
Penalty
Initial $3,000 · Current $1,750 Reduced
29 CFR 1926.451(b)(2):   Scaffold platforms and walkways were not at least 18 inches wide:      a)  Worksite, Front of home - Employee was installing plywood sheathing while working off of a single 2x8in plank approximately 11ft above the ground.      b)  Worksite, Rear of home - Employee was installing plywood sheathing while working off of a single 2 x 8in plank approximately 9ft above the ground.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3000

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 23, 2012
Abate by
Mar 26, 2012
Penalty
Initial $3,000 · Current $1,750 Reduced
29 CFR 1926.451(g)(1):  Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:      a)  Worksite, Front of home - An employee was installing plywood sheathing while standing on a single scaffolding plank.  The employee was working on the edge of the building and was exposed to a fall of approximately 11ft to the ground below; on or about 02/24/12.          Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3000

1926.501 B04 I

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 23, 2012
Abate by
Mar 26, 2012
Penalty
Initial $3,000 · Current $1,750 Reduced
29 CFR 1926.501(b)(4)(i):   Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.      a)  Worksite, Interior - Employees were walking and working around an open basement staircase; on or about 02/24/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3000

View LA Bella Home Improvements's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331921239.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.