OSHA Inspection: LITTLE VILLAGE CAR WASH & AUTO REPAIR

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of LITTLE VILLAGE CAR WASH & AUTO REPAIR in 2600 W. CERMAK ROAD, CHICAGO, IL 60608 (NAICS 811192). OSHA activity number 331921338.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Little Village CAR Wash & Auto Repair for free Get an email when a new federal OSHA severe-injury report for Little Village CAR Wash & Auto Repair is published. One employer, no account, unsubscribe in one click.
Site address
2600 W. CERMAK ROAD
City
CHICAGO
State
IL
ZIP
60608
Mailing
2600 W. CERMAK ROAD, CHICAGO, IL 60608
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811192
Employees
12
Ownership type
A

4 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 5, 2012
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.219(d)(1):     Pulleys, any parts of which are seven (7) feet or less from floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and ( o) of this section:     a. North Wall/Washing Area - On or about February 27, 2012, the pulleys for the water pump (GE -Model # 5K213BC205A & Serial # 266/220v) at less than seven (7) feet from the floor were not totally enclosed, thereby exposing employees to the hazards associated with ingoing nip points.
Recent events (3)
  • · A (S) $3000
  • · I (S) $1500
  • · Z (S) $3000

1910.219 E01

Serious 1 instance 5 exposed
Issued
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1):     Where both runs of horizontal belts are seven (7) feet or less from the floor level, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section:     a. North Wall/Washing Area - On or about February 27, 2012, the belt for the water pump (GE - Model # 5K213BC205A & Serial # 266/220v) at less than seven (7) feet from the floor was not totally enclosed, thereby exposing employees to the hazards associated with ingoing nip points.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 5, 2012
Abate by
Apr 12, 2012
Penalty
Initial $1,800 · Current $1,800
29 CFR 1910.304(g)(5):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.    a. North Wall in the Car Washing Area - On or about February 27, 2012, the furthest from the east electric outlet powering decorative lights was not permanent, continuous, and effective, thereby exposing employees to electrical hazards.
Recent events (3)
  • · A (S) $1800
  • · I (S) $900
  • · Z (S) $1800

1910.305 E01

Serious Gravity 1 3 instances 5 exposed
Issued
Apr 5, 2012
Abate by
Apr 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(1):     Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations.    a. Three outlets on the North Wall in the Car Wash Area- On or about February 27, 2012, employees washing cars were exposed to electric outlets that were not completely enclosed or covered. Employees were thereby exposed to electrical hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331921338.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.