OSHA Inspection: ROYAL SOVEREIGN

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ROYAL SOVEREIGN in 2 VOLVO DRIVE, ROCKLEIGH, NJ 07647 (NAICS 423420). OSHA activity number 332425495.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Royal Sovereign for free Get an email when a new federal OSHA severe-injury report for Royal Sovereign is published. One employer, no account, unsubscribe in one click.
Establishment
ROYAL SOVEREIGN
Site address
2 VOLVO DRIVE
City
ROCKLEIGH
State
NJ
ZIP
07647
Mailing
2 VOLVO DRIVE, ROCKLEIGH, NJ 07647
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423420
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 30 exposed
Issued
Jun 15, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.37(a)(3):     Exit route(s) were not kept free and unobstructed:      a) 2 Volvo Drive, Rockleigh, NJ - An exit located in the warehouse was blocked by the storage of product, on or about 1/30/12.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1910.37 B04

Serious Gravity 10 1 instance 30 exposed
Issued
Jun 15, 2012
Abate by
Jun 22, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.37(b)(4):     Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:        A) 2 Volvo drive, Rockleigh, NJ- warehouse: Exit directional signs were not posted in the warehouse which indicate the direction to the nearest exit, on or about 01/30/12.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.178 L01 I

Serious Gravity 5 30 exposed
Issued
Jun 15, 2012
Abate by
Jul 9, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.178(l)(1)(i):     The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    A) 2 Volvo Drive, Rockleigh, NJ: Employees were not trained to operate powered industrial trucks, on or about 01/30/12.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.305 D02

Serious Gravity 10 1 instance 30 exposed
Issued
Jun 15, 2012
Abate by
Jun 22, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.305(d)(2):     Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.      a) 2 Volvo Drive, Rockleigh, NJ- warehouse: An electrical panel did not have a dead front which exposed employees to electrical injuries from exposed wires when using it to turn the lights on and off, on or about 01/30/12.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.303 G01 II

Serious Gravity 1 30 exposed
Issued
Jun 15, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.303(g)(1)(ii):     Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.    A) 2 Volvo Drive, Rockleigh, NJ: The space in front of the electrical panel was used for the storage of battery jacks and a pallet jack, on or about 01/30/12.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $2100

1910.141 D02 II

Other-than-serious 1 instance 30 exposed
Issued
Jun 15, 2012
Abate by
Jun 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii):     Lavatories were not provided with hot and cold, or tepid running water:    A) 2 Volvo drive, Rockleigh, NJ- women's bathroom by conference room: No tepid water was provided for employees to wash hands, on or about 01/30/12.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332425495.