OSHA Inspection: ARW ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARW ROOFING, INC. in 111 W. OLIVE, ARLINGTON HEIGHTS, IL 60004 (NAICS 238160). OSHA activity number 332426766.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ARW Roofing, INC. for free Get an email when a new federal OSHA severe-injury report for ARW Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ARW ROOFING, INC.
Site address
111 W. OLIVE
City
ARLINGTON HEIGHTS
State
IL
ZIP
60004
Mailing
P.O. BOX 1379, CRYSTAL LAKE, IL 60039
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
13
Ownership type
Private (A)

5 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 6 instances 13 exposed
Issued
Mar 29, 2012
Abate by
Mar 30, 2012
Penalty
Initial $4,900 · Current $3,000 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a) Lower Roof Deck - Employees were exposed to the hazard of falling approximately 16 feet from the roof edge to grade while required to dispose of roofing materials and debris where fall protection had not been provided.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4900

1926.502 J07 I

Serious Gravity 10 2 instances 13 exposed
Issued
Mar 29, 2012
Abate by
Mar 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(j)(7)(i): Materials and equipment were stored within 6 feet (1.8 m) of a roof edge where guardrails were not erected at the edge:    a) Upper Roof Deck - Employees were exposed to the hazard of falling approximately 23 feet from the north edge of the roof deck to grade where roofing materials were stored within 6 feet of the roof edge without fall protection.    b) Upper Roof Deck - Employees were exposed to the hazard of falling approximately 7 feet from the west edge of the roof deck to a lower roof deck where a generator was stored within 6 feet of the roof edge without fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B10

Serious Gravity 10 13 instances 13 exposed
Issued
Mar 29, 2012
Abate by
Mar 30, 2012
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:    a) Lower Roof Deck - Employees were exposed to the hazard of falling approximately 16 feet from the roof edge to grade while engaged in roofing activities without the use of fall protection or safety monitoring.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4900

1926.404 B01 II

Other-than-serious 1 instance 14 exposed
Issued
Mar 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    a) Employees were provided with a Honda 6500 watt generator without having been provided with GFCI protection for cord and plug tools and equipment.    No abatement certification or documentation required for this violation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.405 A02 II J

Other-than-serious 1 instance 13 exposed
Issued
Mar 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not designed for hard or extra-hard usage:    a) A temporary relocatable power tap device that was not designed for hard or extra hard use was provided to supply electricity to tools and equipment at the worksite.    No abatement certification or documentation required for this violation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View ARW Roofing, INC.'s full OSHA safety record →