Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: GORD INDUSTRIAL PLASTICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GORD INDUSTRIAL PLASTICS, INC. in 1310 E. 6TH STREET, SANDWICH, IL 60548 (NAICS 326199). OSHA activity number 332428804.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gord Industrial Plastics, INC. for free Get an email when a new federal OSHA severe-injury report for Gord Industrial Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1310 E. 6TH STREET
City
SANDWICH
State
IL
ZIP
60548
Mailing
1310 E. 6TH STREET, SANDWICH, IL 60548
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
29
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Nov 5, 2012
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energization, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    Entire facility:  the employer did not establish a program for the control of hazardous energy (lockout/tagout) for maintenance employee(s) performing servicing or maintenance on machines and equipment such as but not limited to injection molding machines, grinders and granulators.  Program requirements include:    1) Identification of hazardous energy sources   2) Documentation of machine-specific energy control procedures  2) Employee training and certification (documentation) of training  3) Periiodic inspections and their certification (must be conducted at least annually)    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $0
  • · Z (S) $2975

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.335(a)(1)(i):  Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    Maintenance employee(s) who performed live voltage measurements (240v to 480v) on equipment during servicing and repair did not wear appropriate electrical protective equipment, including but not limited to the following, to protect against electrical shock and arc flash/blast injuries:    a)     Rubber insulating gloves with leather protectors.  b)     Arc-Rated clothing such as arc-rated long-sleeve shirt and pants or arc-rated coverall  c)     Hearing protection (canal inserts)  d)     Arc-rated flash suit hood or balaclava    Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).    Abatement Note:  For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
  • · I (S) $2975
  • · Z (S) $2975

1910.335 A01 IV

Serious Gravity 5 1 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.335(a)(1)(iv): Employees exposed to the danger of head injury from electric shock or burns due to contact with exposed energized parts did not wear nonconductive head protection:    Maintenance employee(s) who performed live voltage measurements (240v to 480v) while servicing and repairing equipment did not wear nonconductive head protection, such as hard hats with die-electric properties, to protect against electrical shock, burns and arc flash/blast.    Abatement certification is required in accordance with 29 CFR 1903.19(c).    Abatement Note:  For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2975

1910.335 A01 V

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face:    Maintenance employee(s) who performed live voltage measurements (240v to 480v) while servicing and repairing equipment, did not wear face protection to prevent burns or injury from flying debris in the event of an arc flash or blast.    Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).    Abatement note:  For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2975

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l)    The employer did not certify an evaluation of each powered industrial truck operator's performance prior to operating a vehicle in the workplace for the first time and every three years thereafter.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B02

Other-than-serious 2 instances 2 exposed
Issued
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):  Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling.    a.  #14 Vertical Press.  A relocatable power tap (electrical outlet strip) was used improperly in an industrial setting to provide power for lights near the vertical press in the production area.      b.  #10 Vertical Press.  An electrical pendant box with multiple outlets (110v) was used on the end of a flexible cord to provide a power source for a light near the #10 vertical press.    There is no abatement documentation or certification required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332428804.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.