Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAANI CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of RAANI CORPORATION in 5202 WEST 70TH PLACE, BEDFORD PARK, IL 60638 (NAICS 325620). OSHA activity number 332429521.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Raani Corporation — free Get an email when a new federal OSHA severe-injury report for Raani Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
RAANI CORPORATION
Site address
5202 WEST 70TH PLACE
City
BEDFORD PARK
State
IL
ZIP
60638
Mailing
5202 WEST 70TH PLACE, BEDFORD PARK, IL 60638
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325620
Employees
150
Ownership type
A

11 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 20 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $5,400 · Current $3,000 Reduced
29 CFR 1910.134(c)(1):  In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable:    a.  On or about March 1, 2012, in the facility, employees were required to wear tight fitting respirators when handling chemicals such as but not limited to, nitric acid and ammonia.  The employer failed to develop and implement a written respiratory program which included at a minimum annual fit tests, medical evaluations, training and maintenance procedures.
Recent events (3)
  • — F (S) $3000
  • — C (S) $5400
  • — Z (S) $5400

1910.146 C01

Serious Gravity 10 1 instance 150 exposed
Issued
Jul 10, 2012
Abate by
Jul 31, 2012
Penalty
Initial $6,300 · Current $3,000 Reduced
29 CFR 1910.146(c)(1):  The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces. NOTE: Proper application of the decision flow chart in Appendix A to section 1910.146 would facilitate compliance with this requirement.    a.  On or about March 1, 2012, in the facility, the employer did not evaluate the workplace to determine the presence of permit required confined spaces, thereby exposing employees to hazards associated with confined spaces.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6300
  • — Z (S) $6300

1910.146 C02

Serious Gravity 10 1 instance 150 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2):  If the workplace contains permit spaces, the employer shall inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces.  NOTE: A sign reading DANGER -- PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language would satisfy the requirement for a sign.    a.  On or about March 1, 2012, in the facility, employees were not informed by signs or other equally effective means of the existence, location of, and the danger posed by permit required confined spaces.  The permit required confined spaces not labeled included but were not limited to, propylene glycol storage tanks.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 C04

Serious Gravity 10 30 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(4):  If the employer decides that its employees will enter permit spaces, the employer shall develop and implement a written permit space program that complies with this section. The written program shall be available for inspection by employees and their authorized representatives.    a.  On or about March 1, 2012, in the facility, employees were required to enter permit required confined spaces to perform cleaning operations.  Employees were exposed to hazards associated with entry into permit required confined spaces when the employer did not develop or implement a permit required confined space program to protect against hazardous atmospheres and any other recognized safety or health hazard such as but not limited to, agitators.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $2,700 · Current $3,000
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.    a.  On or about March 1, 2012, in the maintenance shop, employees were exposed to battery acid when required to charge and/or service powered industrial vehicle batteries.  Employees were not provided with an eyewash for quick and suitable flushing of the eyes.
Recent events (3)
  • — F (S) $3000
  • — C (S) $2700
  • — Z (S) $2700

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2012
Abate by
Jul 17, 2012
Penalty
Initial $4,500 · Current $3,000 Reduced
29 CFR 1910.254(d)(9)(iii):  Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions.     a.  On or about May 2, 2012, in the maintenance shop, an employee was required to perform arc welding on stainless steel with a Miller Inert Arc Welder, Model number 0092, serial number M6607018.  The ground conductor had exposed bare wiring and had not been repaired thereby exposing employees to electrocution hazards.
Recent events (3)
  • — F (S) $3000
  • — C (S) $4500
  • — Z (S) $4500

1910.305 J02 IV

Serious Gravity 5 1 instance 30 exposed
Issued
Jul 10, 2012
Abate by
Jul 17, 2012
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location shall be suitable for the location.    a.  On or about May 9, 2012, in the production area, a receptacle located in a wet and/or damp location was not suitable for the location due to a missing enclosure, thereby exposing employees to electrical hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $4500
  • — Z (S) $4500

1910.1026 D01

Serious Gravity 10 5 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $6,300 · Current $3,000 Reduced

Hazardous substances 0689

29 CFR 1910.1026(d)(1):  General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.    a.  On or about May 9, 2012, in the facility, an employee was required to perform welding operations on stainless steel.  The employer had not performed initial monitoring to determine the employee exposure to Chromium (VI) when welding operations on stainless steel occurred.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6300
  • — Z (S) $6300

1910.1028 E02 I

Serious Gravity 10 1 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 0320

29 CFR 1910.1028(e)(2)(i):  Each employer who has a place of employment covered under paragraph (a)(1) of this section shall monitor each of these workplaces and work operations to determine accurately the airborne concentrations of benzene to which employees may be exposed.    a.  On or about March 1, 2012, employees were required to work with raw materials which contain benzene.  The employer had not monitored the workplace and work operations to determine employee exposure to benzene.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1048 D01 I

Serious Gravity 10 1 instance 20 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 1290

29 CFR 1910.1048(d)(1)(i):  Each employer who has a workplace covered by this standard shall monitor employees to determine their exposure to formaldehyde.    a.  On or about March 1, 2012, employees were required to work with raw materials which contain formaldehyde.  The employer had not monitored the workplace and work operations to determine employee exposure to formaldehyde.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.106 D04 III

Other-than-serious 1 instance 150 exposed
Issued
Jul 10, 2012
Abate by
Aug 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(4)(iii):  "Wiring." Electrical wiring and equipment located in inside storage rooms used for Class I liquids shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Class II and Class III liquids, shall be approved for general use.    a.  On or about March 1, 2012, in the flammable storage room, the electric wiring in the inside storage room was not of the type approved for Class I, Division 2 hazardous locations, thereby exposing employees to fire hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Raani Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429521.