Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED AG SERVICES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UNITED AG SERVICES in 1250 1ST AVENUE, CUMBERLAND, WI 54829 (NAICS 424510). OSHA activity number 332429927.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United AG Services — free Get an email when a new federal OSHA severe-injury report for United AG Services is published. One employer, no account, unsubscribe in one click.
Establishment
UNITED AG SERVICES
Site address
1250 1ST AVENUE
City
CUMBERLAND
State
WI
ZIP
54829
Mailing
PO BOX 68, ALMENA, WI 54805
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
3
Ownership type
A

7 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a) Throughout the grain bin storage area; The employer did not provide machine guarding of belts and pulleys such as, but not limited to, the discharge augers on grain bins 2, 3 and 5.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.219 E01 I

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  (a) Throughout the grain bin storage area; The employer did not provide machine guarding of belts and pulleys such as, but not limited to, the discharge augers on grain bins 2, 3 and 5.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 K

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.272(k): Receiving pit feed openings in the grain handling facility, such as truck or railcar receiving pits, were not covered by grates which had a maximum opening width of 2 1/2 inches:  (a) Grain Drag receiving pit; The employer did not provide adequate guarding of the grain drag receiving pit which had missing and bent protective grating with spaces four inches wide or greater.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  (a) Throughout the grain bin facility; Employees were exposed to electrical hazards due to conduits that were broken, disconnected at junctions or cut off with exposed conductors, such as, but not limited to:  1. Bin # 5; On the east side a broken conduit servicing a lighting fixture, and   2. Bin # 5; On the north side an electrical box had one conduit that was disconnected from the box exposing the live conductor insulation to abrasion and one conduit that was cut off with unguarded exposed dead conductors that could be energized, and   3. Between bins # 2 and 3; A flexible conduit servicing a fan motor was disconnected at the junction with the ridged conduit exposing the conductors to abrasion.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.303 B07

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner:  (a) Throughout the grain bin area; Temporary wiring servicing a discharge auger to bin #2 was strung out over the ground, draped over and wrapped around electrical stations, conduit and mechanical equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ii): Temporary wiring shall was not removed immediately upon completion of the project or purpose for which the wiring was installed:  (a) Throughout the grain bin; Temporary wiring that was ran over the ground to service a discharge auger in grain bin #2 for canola storage and operations approximately two years earlier was not removed when the operations were completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 M03

Other-than-serious 1 instance 5 exposed
Issued
Apr 4, 2012
Abate by
Apr 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.272(m)(3): A certification record maintained of each inspection by the employer in the grain facility was not in accordance with 29 CFR 1910.272(1):  (a) Main office; Required maintenance certifications were not recorded on each maintenance inspection of the grain handling equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429927.