CUMBERLAND, WI —
OSHA Inspection: UNITED AG SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNITED AG SERVICES in 1250 1ST AVENUE, CUMBERLAND, WI 54829 (NAICS 424510). OSHA activity number 332429927.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED AG SERVICES
- Site address
- 1250 1ST AVENUE
- City
- CUMBERLAND
- State
- WI
- ZIP
- 54829
- Mailing
- PO BOX 68, ALMENA, WI 54805
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.219 D01
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Throughout the grain bin storage area; The employer did not provide machine guarding of belts and pulleys such as, but not limited to, the discharge augers on grain bins 2, 3 and 5.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.219 E01 I
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) Throughout the grain bin storage area; The employer did not provide machine guarding of belts and pulleys such as, but not limited to, the discharge augers on grain bins 2, 3 and 5.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.272 K
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.272(k): Receiving pit feed openings in the grain handling facility, such as truck or railcar receiving pits, were not covered by grates which had a maximum opening width of 2 1/2 inches: (a) Grain Drag receiving pit; The employer did not provide adequate guarding of the grain drag receiving pit which had missing and bent protective grating with spaces four inches wide or greater.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) Throughout the grain bin facility; Employees were exposed to electrical hazards due to conduits that were broken, disconnected at junctions or cut off with exposed conductors, such as, but not limited to: 1. Bin # 5; On the east side a broken conduit servicing a lighting fixture, and 2. Bin # 5; On the north side an electrical box had one conduit that was disconnected from the box exposing the live conductor insulation to abrasion and one conduit that was cut off with unguarded exposed dead conductors that could be energized, and 3. Between bins # 2 and 3; A flexible conduit servicing a fan motor was disconnected at the junction with the ridged conduit exposing the conductors to abrasion.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.303 B07
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner: (a) Throughout the grain bin area; Temporary wiring servicing a discharge auger to bin #2 was strung out over the ground, draped over and wrapped around electrical stations, conduit and mechanical equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 II
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ii): Temporary wiring shall was not removed immediately upon completion of the project or purpose for which the wiring was installed: (a) Throughout the grain bin; Temporary wiring that was ran over the ground to service a discharge auger in grain bin #2 for canola storage and operations approximately two years earlier was not removed when the operations were completed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.272 M03
- Issued
- Apr 4, 2012
- Abate by
- Apr 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.272(m)(3): A certification record maintained of each inspection by the employer in the grain facility was not in accordance with 29 CFR 1910.272(1): (a) Main office; Required maintenance certifications were not recorded on each maintenance inspection of the grain handling equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 424510)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429927.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.