Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: APPLETON HEALTH CARE CENTER

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of APPLETON HEALTH CARE CENTER in 2915 N. MEADE ST., APPLETON, WI 54911 (NAICS 623110). OSHA activity number 332429992.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Appleton Health Care Center — free Get an email when a new federal OSHA severe-injury report for Appleton Health Care Center is published. One employer, no account, unsubscribe in one click.
Site address
2915 N. MEADE ST.
City
APPLETON
State
WI
ZIP
54911
Mailing
2915 N. MEADE ST., APPLETON, WI 54911
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.305 J01 IV

Other-than-serious 1 instance 3 exposed
Issued
Aug 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(iv):     Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts:    (a) On 3/1/2012, in the kitchen area where carts are sprayed down, the water-protective cover for the plug-in receptacle located on the wall was damaged and would not properly seal, potentially exposing the receptacle to water mist.                                   No Abatement Certification or Documentation is required.
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 2 exposed
Issued
Aug 22, 2012
Abate by
Aug 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i):     The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet:    (a)  Various chemical products used and stored in the maintenance area were not included in the company's chemical inventory list.  The chemicals include, but are not limited to:    *   Ecolab stainless steel clean, containing liquified petroleum gas;  *   Ace paint thinner, containing Stoddard Solvent and  1,2,4-Trimethylbenzene;  *   and, Miniwax polyurethane, containing Stoddard Solvent.                             No Abatement Certification or Documentation is required.
Recent events (1)
  • — Z (O) $0

View Appleton Health Care Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429992.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.