Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STAINLESS TANK & EQUIPMENT

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of STAINLESS TANK & EQUIPMENT in 801 4TH STREET, BELOIT, WI 53511 (NAICS 336212). OSHA activity number 332430222.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stainless Tank & Equipment — free Get an email when a new federal OSHA severe-injury report for Stainless Tank & Equipment is published. One employer, no account, unsubscribe in one click.
Site address
801 4TH STREET
City
BELOIT
State
WI
ZIP
53511
Mailing
801 4TH STREET, BELOIT, WI 53511
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.26 C02 VII

Serious Gravity 1 1 instance 1 exposed
Issued
May 14, 2012
Abate by
May 15, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked and taken out of service until repaired by either maintenance department or the manufacturer.    In the Seam Welder Bay employees were using a damaged ladder to perform welding operation on tanks.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.132 A

Serious Gravity 10 1 instance 1 exposed
Issued
May 14, 2012
Abate by
May 15, 2012
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:      In the Inter Barrel Line B employees are working from the top on the stainless steel tanks with no fall protection.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
May 14, 2012
Abate by
May 17, 2012
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions.   [55 FR 13709, Apr. 11, 1990; 61 FR 9227, March 7, 1996; 70 FR 53929, Sept. 13, 2005]    In the Inter Barrel Line B employees were using a Miller Argon Gas welder that had bare exposed conductors.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

View Stainless Tank & Equipment's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332430222.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.